Brinkmann TURKEY FRYER 815-4001 SERIE Manual Del Propietário página 9

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

GAS LEAK TESTING:
1. Create a mixture of 50% water and 50% liquid
dishwashing soap.
2. To turn on the fuel supply, turn the cylinder
valve knob one turn counterclockwise.
3. Apply the soap water mixture to the following:
A
Supply tank (cylinder) weld
B
Connection nut to cylinder valve
C
Back side of connection nut to brass
nipple
D
Brass nipple connection into regulator
E
Regulator connection to gas supply
hose
F
Gas supply hose connection to
burner assembly
G
The full length of gas supply hose
H
Cylinder valve to cylinder
4. Check each place listed (A-H) for growing
bubbles which indicates a leak.
5. Turn OFF gas supply at cylinder valve.
6. Turn ON control knob to release gas pressure in hose.
7. Turn control knob to OFF position.
8. Tighten any leaking connections.
9. Repeat soapy water test until no leaks are detected. DO NOT use the fryer if leaks cannot be stopped.
Contact a qualified gas appliance repair service.
10. Turn OFF gas supply at cylinder valve until you are ready to use your fryer.
11. Wash off soapy residue with cold water and towel dry.
12. Wait 5 minutes to allow all gas to evacuate the area before lighting fryer.
Note:
The leak test must be performed in an area that has adequate lighting in order to see if
bubbles are developing. DO NOT use a flashlight to check for bubbles.
Watch For Bub bles
F
H
D
C
B
A
E
G
8