THERMAL OVERLOAD PROTECTION ________________
The thermal protector operates to stop the motor when a problem
occurs. If the motor should stop during operation, proceed as
follows.
1. Turn the pressure switch lever to the "OFF" position and
disconnect the plug from the receptacle.
2. If the extension cord does not conform to the proper
specifications, replace with suitable extension cord. If the
capacity of the power supply is insufficient, increase the power
supply capacity to remove the cause of a flow of excessive
current (over-current).
3. Wait approximately 5 minutes, then press the reset button of the
thermal protector.
4. If the motor still stops during operation, please call for service.
A = Thermal Protector