4.3.1 Voltage supply: Sub-D plug, 15-pole, pin assignment
The connection port is located in the cable entrance area.
Pin no. Description
1
-UB
2
-UB
3
-UB
4
-UB
5
6
+UB
7
+UB
8
+UB
9
+UB
10-14
15
Power supply voltage range: 9 V until 72 V DC
Explanations concerning the ignition signal (pin 15)
a) Usage of the ignition signal is optional
b) The ignition function requires a 3-wire voltage supply cable (ACD Art. No. 12100688).
c) The voltage level of the ignition function is 9 V DC to 72 V DC (like the main power supply).
This ignition signal can be derived from the main power supply when using a switching contact.
The voltage for the ignition signal is drawn via "-UB" (pin 1 to 4), i.e. the same ground as the
main power supply voltage.
d) For use of the ignition function see chapter 4.1.2.
The MFT10 must be protected with a 10 A slow-blow fuse at the machine end!
4.3.2 USB
Standard configuration according to USB2.0 standard. Maximum current: 500 mA each
The maximum power consumption should be observed, see section 4.3.8.
The four interfaces are located in the cable entrance area (x2) underneath the cover on the side (x2)
MFT10_Brief Overview_Resumen_breve_FCC_V1.00_en_es
Function
POWER IN-
Power supply 0 V
POWER IN-
Power supply 0 V
POWER IN-
Power supply 0 V
POWER IN-
Power supply 0 V
not assigned
POWER IN+
Power supply +
POWER IN+
Power supply +
POWER IN+
Power supply +
POWER IN+
Power supply +
not assigned
Ignition
Ignition signal, (since revision second edition)
11 / 40