3
Make sure the alignment pins are inserted in their provided seats.
4
Join the uprights and the brackets, using the screws supplied.
5
Reassemble the back panels and any other covering elements possibly supplied.
15. Electric connecti on
DANGER! Live parts. Electrocuti on.
REMOVE THE ELECTRIC POWER SUPPLY BEFORE ANY OPERATION!
ensure that the casing does not come into contact with the electrical panel
Provide a suitable grounding system!
i
The systems must be set up in accordance to the norms that regulate manufacture, installa-
ti on, use, and maintenance foreseen by the norms in force in the country where the refrige-
rati on system is installed.
To ensure normal operati on, the maximum variati on of the voltage must range between +/-
6% of the nominal value.
Liability
Power
• the supply lines of the electric energy should meet the requirements of power
power supply
• check that the power line:
• has wires with suitable cross secti on
• be protected against overcurrent and leakage to the ground in compliance
• for the power supply lines measuring more than 4-5 m, increase the secti on
Automati c
• protect the upstream cabinets with omnipolar circuit breakers with suitable
safety switches
• instruct the operator on the positi on of the switches to be reached quickly in
05060165 00 15-04-2016
B e l g r a d o 2 - L o n d o n 3
Customer
provide a power line to the cabinet connecti on point.
Installer
provide the anchoring devices for all the wires in input and ou-
tput to/from the cabinet.
ARNEG
ARNEG S.p.A. denies all liability with respect to the user or third
parti es for:
- damages caused by failures or malfuncti on of the systems
installed upstream of the cabinet
- damages to the cabinet due to causes arising directly from
malfuncti on of the electrical system
consumpti on of the cabinet (chap.10).
with the regulati ons in force.
of the cables appropriately.
i
The replacement of the damaged power cord is reserved to the manu-
facturer or a body authorized by the same.
characteristi cs that will also have the functi on of master switches for cutti ng
off the line
case of EMERGENCY
DANGER! Live parts. Short circuit Electrocuti on
The automati c magneto-thermal switches must be such that they do
not open the circuit on the neutral, without simultaneously opening
on the phases and, in any case, must allow complete disconnecti on
in conditi ons of category III overvoltage.
V D L -V D A -S E L F -8 3 -H 125-H 150
E n g l i s h
45