LUX-top
G-T
DIREKT WD / DIREKT WD II
®
The LUX-top
G-T retaining foot required for assembly is available for a wide variety of
mounting substrates - please contact the manufacturer ST Quadrat if necessary!
Mount the retaining feet according to the installation instructions and then seal in.
Approved fixing surface:
Steel trapezoidal profiles
(t min = 0.75 mm)
Depending on static requirements,
provide
accordance
12.2.8 (Figure 12.15)!
a) Place the base plate on the
b) Die Use the base plate as a
c) Drill the attachment holes
d) Position
e) Tighten
ST QUADRAT Fall Protection S.A. – Your competent partner for fall protection solutions – www.lux-top-absturzsicherungen.de
reinforcing
plates
with
IFBS
Chapter
raised
portions
of
trapezoidal sheet.
template for marking the
drill holes.
(Ø
24mm)
with
optionally
available
counterbore.
the
base
plate's
keyholes over the drill holes
in
the
trapezoidal
sheet.
Feed the folded toggle bolts
through the drill holes and
unfold them by moving the
bolt.
the
bolts
the toggle bolts firmly sit
against the inside of the
trapezoidal
sheet.
Use
torque wrench (13 Nm).
Page 22 Version 05/2019
- retaining foot
Befestigungsuntergrund:
Betonbauteile
Festigkeitsklasse mind. C20/25 (B25)
in
a) Place the retaining foot parallel to the edge of
the
the roof at the desired position.
b) Drill holes through the holes in the retaining
foot - foot plate. Thoroughly clean the holes.
(brushing and blowing out) !!!
an
c) Drive in the concrete anchors and apply the
appropriate torque. Use a torque wrench.
Baseplate dimensions [mm]
Anchor bolt
Drill hole-Ø [mm]
Min. drilling depth / depth of
until
anchoring into concrete [mm]
a
Tightening torque [Nm]
Min. component thickness [mm]
Min. edge distance anchor bolt
[mm]
150x150x6
(4-Loch)
FAZ II 10/20
A4
10
75 / 60
45
110
250