General assembly and installation requirements:
max.
0.40 m
Start, end and
corner post
4 slabs @ 11.5 kg
* max. 0.50 m in EN ISO 14122-3
Openings between the edge protection systems and other constructions must be as small as
possible, however, must not exceed 120 mm for principle guardrails and 20 mm for the
toeboard.
Only concrete paving slabs 50x25 cm with a maximum thickness of 5 cm and at least 11.5 kg
weight each may be used as weighting material.
®
The
LUX-top
G-T / LUX-top
end post. These must be equipped with a double weight (see schematic diagram).
During the preparation phase: Roughly spread the basic elements, counterweight holders and
concrete slabs along the length of guardrail to be installed in line with the installation
requirements.
ST QUADRAT Fall Protection S.A. – Your competent partner for fall protection solutions – www.lux-top-absturzsicherungen.de
max.
2.0 m
Clear size
max. 0.47
m
*
Clear size
max. 0.47
m
*
L = 1.30 m
W = 0.55
m
®
G-T ECO
Page 16 Version 05/2019
max.
max.
0.40 m
2.0 m
Intermediate post
2 slabs @ 11.5 kg
must always consist of at least one start and one
A diagonal member is
required in each
section / module!
Parapet height min. 50 mm!
A toeboard is required where parapet
heights are less than 150 mm!
Figure by way of
example
H = 1.15 m