Please read the instructions carefully before assembling or using the
equipment.
SAFETY
HEAT EXCHANGER RISKS
These heat exchangers have been manufactured using modern technology and following
safety good practices. In spite of this, some risks could appear due to wrong use. In order
to avoid these situations, the installer must follow the installation procedures which are
included in this manual and use the device for what was designed.
¡It is for your safety! Next instructions relative to safety use next symbols:
It means direct health risk. If this information is not followed It could
lead to serious injuries
DANGER
It means that it could lead to health risk. If this information is not
followed It could damage people health
CARE
It means that it could lead to health risk. If this information is not
followed It could lead to damage people or things
PRECAUTION
It means that this issue contains important information for using
correctly the device.
If this information is not followed the device or the enviroment
could be damaged.

GENERAL USE

The heat exchanger has been only designed to heat the pool water by means of a boiler.
The water quality must be within the following limits.
HCLO + CLO:
pH:
CHLORIDES:
ISOCIANURIC ACID:
CaCo3:
HBrO:
Do not exceed these limits!
The flow rate of water entering the heater must not exceed:
Heating element (MAIN)
Pool water (SECONDARY)
4 ppm
6 – 8
up to 250 ppm
up to 100 ppm
up to 250 ppm
up to 008 ppm
10 bar máx.
3 bar máx.
- 2 -
Salt:
4 – 6 gr/l