INSTALLATION
Install the heat exchanger only in areas with a non aggressive atmosphere and free of
frost. Any drop on it could damage it.
A free access for install/des install must be granted.
The heat exchanger can be installed under/ or over the water level.
Next values related to the heat exchanger must be taken into
account;
PRECAUTION
Max Cl content
Max free Cl
PH
Salt
PRIMARY MAX water pressure
SECONDARY MAX water pressure
¡Important!
Meanwhile the boiling cycle is on, the heat exchanger never can
be drained from the water pool side.
ASSEMBLY
Check that there are not evident heat exchanger damages before assembling it.
The heat exchanger can be installed in horizontal or vertical under or over the water level.
ASSEMBLY DIAGRAM
Models:
TITANIUM DOUBLE: 44738 / 44739 / 44740
500 mg/l
3000 mg/l
1,3 mg/l
limitless
6,8 a 8,2
6,8 a 8,2
4 – 6 gr/l máx.
10 bar
3 bar
1 0º
- 6 -
OK
OK
No OK