Troubleshooting Guide - Swisher E4-U3000 Manual Del Usaurio

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting Guide

What To Check
Does the engine crank?
YES
Good compression?
YES
Does the tank contain
fresh fuel of the proper
grade?
YES
Is fuel visible and moving
in the return line when
priming?
YES
Is there spark at the spark
plug wire terminal?
YES
Check the spark plug.
ENGINE DOES NOT START
Possible Cause
Faulty recoil starter.
NO
Fluid in the crankcase.
Internal damage.
Loose spark plug.
NO
Excess wear on cylinder, piston,
rings.
Fuel incorrect, stale, or contaminated;
NO
mixture incorrect.
Check for clogged fuel filter and/
NO
or vent.
The ignition switch is in "O" (OFF)
position.
NO
Shorted ignition ground.
Faulty ignition unit.
If the plug is wet, excess fuel may be in
the cylinder.
The plug is fouled or improperly gapped.
The plug is damaged internally or of the
wrong size.
Remedy
Consult with an authorized servicing
dealer.
Tighten and re-test.
Consult with an authorized servicing
dealer.
Refill with fresh, clean unleaded gasoline
with a pump octane of 87 or higher
mixed with a premium 2-cycle mixing oil
or with an equivalent high quality 2-cycle
mixing oil.
Replace fuel filter or vent as required.
Restart.
Move switch to "I" (ON) position and
restart.
Consult with an authorized servicing
dealer.
Crank the engine with the plug removed,
reinstall the plug, and restart.
Clean and regap the plug to .024" /
0.6mm-0.7mm. Restart.
Replace the spark plug. Check the
"Specifications" section for the correct
plug for your unit. Restart.
15

Publicidad

Tabla de contenido
loading

Productos relacionados para Swisher E4-U3000

Tabla de contenido