LOCATION AND LEVELLING

ATTENTION: this ice equipment has been designed to be installed in
areas where the room temperature do no exceed the maximum of 40 º C
nor the minimum of 10 º C
Prolonged period of operation with temperature different ot the
mentioned represents a wrong use of the equipment and suppose the
nullity of the guarantee.
ELECTRICAL CONNEXIONS
To choose the kind and section of the cable observe the ampère indicated in
the plate of the equipment.
All the equipments has an electric supply cable, so it is needed a conection
to the electric line equipped with earth cable and with magnetothermic
switch with fuse appropriate as it is indicated in the plate of each equipment.
The maximum ampere variation permitted does not have to exceed a 10%
of the plate or be less than a 10% of the same.
A lower ampère can produce an anomalous operation and make damage
seriously the protection device and the electric winding.
NOTE: All the external connexions has to be perfect, according with the local
laws. In some cases it is needed the intervention of a qualified electrician..
Before connecting the ice equipment with the electric line, check the ampère
again of the unit, detail in the plate, with the correspondent ampère of the
electric supply.
WATER AND DRAIN CONNEXION
- General
When choosing the water line for the modular crush and supercrush ice
equipment of model MF take care of the following: la serie MF,
a) Length of the line
b) Clear and pure water
c) Suitable pressure of the line.
4
Water is the most simple and important ingredient for making ice, for this
resason the previous points are very important. A low pressure of water,
below 1 bar can origin problem with the operation of the unit.
Water that contains and excess of minerals can produce a residuum sheet
in the inner parts of the water system, meanwhile a soft water containing
lower mineral salts produce a granular ice too "dry".
ATTENTION: Using soft water (lower mineral salt) with less electric
conductivity of 30 mS don't let the low tension electricity to go
through between the sensors of water level, causing the stop or wrong
function of the unit.
Chlorine water or ironish water can be partially improve with active coal
filters.
- Inlet of water
Connect the male connector to the water inlet of 3/4" Gas to the water line
using a reinforced plastic pipe with non-polsonous material for food or a
copper pie with external diameter of 3/8".
The inlet water line has to have a stopcock located in an accessible place
near the unit. If water has a high level of impirites it is recommended to install
a fitler or a purifier to prepare it appropriately.
-
Water inlet – Water cooling models
The models cooled with water need two separate inlet lines; one for the tank
and the other one has to go through one adjustment mechanic valve to the
cooling condenser.
Also for the water connection of the condenser use a reinforced plastic
flexible pipe or a copper pipe of 3/ 8 with female connector of+" Gas and a
separet bypass valve.