NOTE: in the air cooled models, the condensation pressure remain
between two values preestablished throught the fan, sending
intermittently through the sensor located in the wings' condenser.
If the condensation temperature reach to 70 º C due to
and obstruction in the condenser and/or the motor of the
fan do not work, the sensor temperature of the condenser
stop the unit and consequently a RED LIGHT of danger is
switch on.
After diagnosing and solving the problem, repit the operation indicated in
the previous "Note" to start up again the unit.
E. Check the correct functioning of the water level sensor, close the
stopcock. After some minutes when the level of water
Go down the sensor, the unit will stop and inmediately
switch on the YELLOW LIGHT showing the lack of water.
NOTE: The water level sensor detects the presence of inadequate quantity
of water in the tank and it confirms it to the microprocessor manintining an
electric low ampère flow through the sensors using the water as a
conductive material.
ATTENTION. To use demineralize water (water whitout or with little
salt) with a electric conductivity of less than 30 mS not allow the
lower tension electricity to pass making the unit to stop or not
functioning, a YELLOW LIGHT swith one showing a lack of water.
After open again the stopcock, the YELLOW LIGHT switch off automatically
and a RED LIGHT is flashing. After 3 minutes the unit start up again, first
the reduction gear and after 5 seconds the compresor.
6
F. Check the correct function of ice level control electronic eyes, put the
hand between the two sensor located in the outlet pipe. (one in every
pipe in model MF61). In this way it is interrumped the beam and switch
off the RED LIGHT located in the front side of the electroic
Card. After 6 second the unit stops automatically and switch
On the YELLOW LIGHT showing the situation FULL CABIN.
The beam of light is retablished after 6 seconds, the unit will start up
Automatically (after de 3 minutes of delay) and the yellow
Light that has been switched on before.
NOTE. The control level of the ice (infrared system) is independent of the
temperature, otherwise it can be affected for the external light and the dirty or
lime deposits located directly in the eyes(infrared sensors).
For a correct operation of the unit it necessary to install it far away of direct
point of light and to scrupulously observe the points mentioned in the
maintenance of the eyesde los ojos.
G. If they are instaled take out the auxiliar manometers and install again the
frontal panel that have been taken before.
H. Explain to the owner the function of the ice equipment as well as the
cleaning and maintenance of the same.