PROBLEM
CAUSE
Fuse of the board
Electronic blown
Main switch unplug
The unit doesn't work
(any light switch on)
Electronic board
Damage
Electric cables cut
(Yellow light of tank full
Optical control of filling dirty
switch on)
Or damage
Water not arrive to the tank
Yellow light of lack of water Demineralized water
Switch on
Sensors with lime
Excessive condensation
temperature
(Red light switch on)
Room temperature
Very low
3 minutes of delay
(Red light flashing)
(Yellow light of turn
High evaporation temperature
flashing)
Lack of refrigerant
TROUBLESHOOTING
MEASURE TO TAKE
Sustitute the fuse and find out
The problem
Connect the switch
Sustitute the electronic board
Check the cables
Clean or substitue the optical
Control
Check solution for the lack of
Water
Install a dosing for mineral salts
Remove lime descaling
Product
Condenser dirty. Clean
Fan motor burnt substitue
Move the unit to a suitable room
(+ of 1º ©)
Wait 2 minutes
Check the refrigerant
PROBLEM
CAUSE
(Yellow light of turn
The gear motor turn on
Flashing)
The other way round
Low voltaje
The compresor works
intermittently
Rusty contacts in the contactor Clean or substitute
No condense gases in the
system
Cable in the compressor
Loose
Capillary pipe parcially
Obstruct
Humidity in the system
Lack of water in the evaporator Check solution for lack of water
Few production of
Ice
Lack of refrigerant
Excess of refrigerant
Level of water tank very low
Shaft / Evaporator dirty
Or damage
MEASURE TO TAKE
Check the stator and the condenser
Of work in the reduction gear
Check the circuit for overwork
Check the power supply
If there is low voltage check with
The electric company
Discharge the refrigerant, and
Charge again
Check all the connections
Check the circuit if there is overwork
Check power supply
If there is low voltage check with
The electric company
Make the same as in thebefore section
Look for leak of refrigerant and
Charge again
Check and adjust the refrigerant
Raise the tank or water level
Substitute axis/evaporator