Descargar Imprimir esta página
LiftMaster RSW12U Guia De Inicio Rapido
Ocultar thumbs Ver también para RSW12U:

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

QuickStar t
for single gate application
2016 UL 325 Gate Operators require use of LiftMaster
external monitored entrapment protection devices.
This QuickStart is intended to highlight a single gate
application. Each application is unique and it is the
responsibility of the purchaser, installer and end user to ensure
that the total gate system is installed and operated properly.
Refer to the installation manual for complete information
regarding installation, testing, and programming.
845 Larch Avenue
Elmhurst, Illinois 60126-1196
LiftMaster.com
01-38137
© 2016, LiftMaster – All Rights Reserved
Determine location for concrete pad
and operator.
Dimension (A) thru (E) are from
the center of one pivot point to
the center of another pivot point.
D
minus 10" (25.4 cm)
10" (25.4 cm)
Distance
Chart A
DISTANCE
46"
35.5"
29.5"
35"
11"
45"
(116.8 cm)
(90.1 cm)
(74.9 cm)
(88.9 cm)
(27.9 cm)
(114.3 cm)
46.8"
35.5"
33.5"
42"
11"
37"
(118.7 cm)
(90.1 cm)
(85.1 cm)
(106.7 cm)
(27.9 cm)
(94 cm)
46.8"
37"
31.5"
40"
11"
41"
(118.7 cm)
(94 cm)
(80 cm)
(101.6 cm)
(27.9 cm)
(104.1 cm)
47.3"
37.3"
30"
37"
11"
45"
(120 cm)
(94.6 cm)
(76.2 cm)
(94 cm)
(27.9 cm)
(114.3 cm)
47"
35"
29.5"
32"
11"
45"
(119.4 cm)
(89 cm)
(74.9 cm)
(81.3 cm)
(27.9 cm)
(114.3 cm)
42.5"
33"
26.5"
28.5"
11"
41"
(108 cm)
(83.8 cm)
(67.3 cm)
(72.4 cm)
(27.9 cm)
(104.1 cm)
Chart B
DISTANCE
34.5"
34.8"
29.5"
35"
14"
43"
(87.6 cm)
(88.3 cm)
(74.9 cm)
(88.9 cm)
(35.6 cm)
(109.2 cm)
44"
36.5"
32.5"
42"
14"
32"
(92.7 cm)
(82.6 cm)
(106.7 cm)
(35.6 cm)
(81.3 cm)
(111.8 cm)
44"
37"
30.5"
40"
14"
40"
(111.8 cm)
(94 cm)
(77.5 cm)
(101.6 cm)
(35.6 cm)
(101.6 cm)
43"
45"
37"
30.5"
37"
14"
(114.3 cm)
(94 cm)
(77.5 cm)
(94 cm)
(35.6 cm)
(109.2 cm)
44.8"
35.8"
29.5"
32"
14"
44"
(113.7 cm)
(90.8 cm)
(74.9 cm)
(81.3 cm)
(35.6 cm)
(111.8 cm)
41"
39"
27.5"
28.5"
14"
41"
(104.1 cm)
(99.1 cm)
(69.9 cm)
(72.4 cm)
(35.6 cm)
(104.1 cm)
INSTALLATION
Install conduit and pour concrete pad.
Attach the operator to the concrete pad.
4.5" (11.4 cm)
Conduit location
4" (10.2 cm)
3" (7.6 cm)
10" (25.4 cm)
15" (38.1 cm)
24" (61 cm)
6" (15.2 cm) Above
Ground
Below the frost line. Check
all national and local
codes. Minimum of 24"
(61 cm) recommended in
regions with no frost line.
28" (71.1 cm)
24" (61 cm)
Weld long arm, short arm, and gate bracket.
Position the gate bracket.
46" (116.8 cm)
Adjust the operator arm length.
Install the cover.

Publicidad

loading

Resumen de contenidos para LiftMaster RSW12U

  • Página 1 6" (15.2 cm) Above Ground Below the frost line. Check all national and local Distance 2016 UL 325 Gate Operators require use of LiftMaster codes. Minimum of 24" Chart A (61 cm) recommended in external monitored entrapment protection devices. regions with no frost line.
  • Página 2: Wiring And Adjustments

    1. Open and close the gate with the test buttons, ensuring that the breaker. Connect the earth ground rod, incoming power, system and REQUIRES the addition of a LiftMaster external INITIAL LIMITS AND FORCE ADJUSTMENT gate is stopping at the proper open and close limit positions.
  • Página 3: Démarrage Rapide

    Vérifier tous les codes Distance nationaux et locaux. Une l’utilisation de dispositifs externes surveillés de Tableau A hauteur de 61 cm (24 po) protection de LiftMaster contre le piégeage. au minimum est DISTANCE recommandée dans les régions sans ligne de gel. 116,8 cm...
  • Página 4 EXIGE l’ajout d’un système externe surveillé de l’alimentation principale. Connecter la tige de mise à la terre, fermeture. protection de LiftMaster contre le piégeage (capteur photoélectrique 1. Enfoncer et relâcher les l’alimentation entrante, la batterie et le transformateur...
  • Página 5: Instalación

    (14 pulg.) (44 pulg.) LiftMaster.com 104.1 cm 99.1 cm 69.9 cm 72.4 cm 35.6 cm 104.1 cm (41 pulg.) (39 pulg.) (27.5 pulg.) (28.5 pulg.) (14 pulg.) (41 pulg.) 01-38137 © 2016, LiftMaster – Reservados todos los derechos de ley...
  • Página 6 Conectar la jabalina de puesta a tierra, la alimentación 1. Pulsar y soltar monitoreada de LiftMaster para CADA zona de atrapamiento eléctrica, la batería y el transformador (ver las siguientes 2. Colocar un objeto sólido entre la trayectoria de apertura y una simultáneamente los botones...