TROUBLESHOOTING
PROBLEM
The fan seems
louder than it should
The fan is not
clearing the room
LIMITED 5-YEAR WARRANTY
If this product fails due to a defect in materials or workmanship at any time during the first FIVE years of ownership, the
manufacturer will replace it free of charge, postage-paid at their option. This warranty does not cover products that have
been abused, altered, damaged, misused, cut or worn. This warranty does not cover use in commercial applications. Use
only manufacturer-supplied genuine warranty repair replacement parts to repair this fan. Use of non-genuine repair parts
will void your warranty. The manufacturer DISCLAIMS all other implied or express warranties including all warranties of
merchantability and/or fitness for a particular purpose. As some states do not allow exclusions or limitations on an implied
warranty, the above exclusions and limitations may not apply. This warranty gives you specific legal rights, and you may
have other rights that vary from state to state.
This warranty is limited to the replacement of defective parts only. Labor charges and/or damage incurred during installation,
repair, replacement as well as incidental and consequential damages connected with the above are excluded. Any damage
to this product as a result of neglect, misuse, accident, imporper installation or use other than the purpose SHALL VOID
THIS WARRANTY.
Shipping costs for return product as part of a claim on the warranty must be paid for by the customer.
Inquiries regarding warranty claims can be directed to 1-866-994-4148, 8 a.m. - 6 p.m., EST, Monday - Thursday,
8 a.m. - 5 p.m., EST, Friday.
POSSIBLE CAUSE
CFM too great
Damper not working properly or
damaged
Bend in duct too close to fan discharge
Fan discharge reduced to fit smaller
duct
Fan body not securely attached
Insufficient intake airflow within room
Insufficient CFM
CORRECTIVE ACTION
Be sure the CFM rating on the fan
matches the size of your room
Check damper to ensure it is opening
and closing properly. If the damper
has become damaged, please call
Customer Service
Be sure you do not have any sharp
bends in duct closer than 18 in. to the
fan discharge
Use recommended size ducting to
reduce fan noise
Be sure the fan is securely attached
to your ceiling joists
Be sure a door or window is slightly
ajar or opened to allow airflow. The
fan is not able to draw air out of the
room without enough airflow to draw
from
Be sure the CFM rating on the fan
matches the requirements for your
room size
NOTE: Using a tissue is not an
accurate method for determining if
the fan is operating properly. If the
fan clears steam from the room
within approximately 15 minutes of
completing your shower, then the
fan is operating properly
12