Change of Filters

In General
When replacing the filters, the necessary precautions to
protect the environment and the respiratory passages of
the operator must be taken. The nature and scope of these
precautions must be based upon the type of dust being on the
surface of the filters. Before checking or replacing the filters,

Check and Replacement of the Membrane Filter

Pull off the pre-filter / membrane filter from the adapter ring /
upper part where it is fastened.
• Loosen the four container clips attaching the motor top to
the collection container and remove the motor top.
• Place the motor top upside down upon a dry and clean
surface.

Replacing the HEPA-filter (Item no. 84.67.5006)

you must clean the filters as previously described, and you
must empty the machine. The filters are to be handled in a way
not causing any danger, and the safety equipment must be
appropriate for the job.
Inspect the filter; are there any signs that the membrane is
damaged, and/or is the filter material torn?
A damaged or worn filter must be replaced.
A replacement of the membrane filter should also include a
replacement of the HEPA-filter.
• Loosen the four container clips attaching the motor top to the collection container
and remove the motor top. Place the motor top in a way that allows access to the
filter.
• Pull off the membrane filter to gain access to the HEPA-filter
EN