Interfaces
Value range
0x82: Reset device parameters to factory defaults
0xA5: Calibrate vacuum sensor of all ejectors
0xA7: Reset erasable counters in all ejectors
0xA8: Reset voltage min/max
Default value
-
Unit
-
EEPROM
no
Extended device locks
Parameter
90 (0x005A)
Description
Extended device locks
Index
-
Datatyp
uint8
Length
1 Byte
Access
read/write
Value range
Bit 0: NFC write lock
Bit 1: NFC disable
Bit 2: local Ejector-Firmware update locked
Bit 3: local user interface locked (manual mode in ejectors locked)
Default value
-
Unit
-
EEPROM
yes
PIN code
Parameter
91 (0x005B)
Description
Pass code for writing data from NFC app
Index
-
Datatyp
uint16
Length
1 Byte
Access
read/write
Value range
0: No PIN code
1 ... 999: PIN code for NFC
Default value
0
Unit
-
EEPROM
yes
Valor de ajuste para punto de conmutación H1 de los eyectores
Parameter
100 (0x0064)
Description
Setpoint H1 for ejectors
Index
0...15 Index corresponds to ejector number #1...#16
Datatyp
uint16
Length
32 Byte
Access
read/write
Value range
998 >= H1 >= (H2+h1)
36 / 72
ES · 30.30.01.01598 · 02 · 01/19