4.5.

Every 6 months:

Change the oil. For this purpose, remove the oil dipstick, remove the oil drain plug beneath
the compressor and allow the oil to drain into a container.
Only perform an oil change when the compressor is warm as this ensures that it is drained
quickly and completely. Re--install the oil drain plug and fill in oil up to the maximum level.
The oil quantity required is 0.36 litres.
Oil is an environmental pollutant. Contact the responsible authorities
regarding disposal.
Clean all ribbed parts of the compressor. This ensures good performance of the cooling sys-
tem and lengthens the service life of the machine.
4.6.

Every 2 years:

Check the valves and replace as necessary.
Clean or replace the sinter filter in the separator
4.7.

Maintenance schedule

Maintenance work
Oil level check
Drain condensation
water
Clean intake filter
Oil change
Clean compressor
Check/
replace valves
Clean/
replace sinter filter
Weekly
X
X
500--hour maintenance by qualified personnel:
Every
Monthly
6 months
X
11
Every
2 years
X
X
X
X