Troubleshooting Guide - 3M Aqua-Pure AP800 Serie Instrucciones De Uso E Instalación

Ocultar thumbs Ver también para Aqua-Pure AP800 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

FILTER CARTRIDGE REPLACEMENT INSTRUCTIONS
To reduce the risk associated with property damage due to water leakage:
• The disposable fi lter cartridge must be replaced every six months or at the specifi ed service cycle.
The contaminants or other substances reduced by this water filter are not necessarily in all user's water.
Filter life depends on local water conditions and the volume of water used. We recommend you change your filer as pre-
scribed by the filter documentation. However, it can be replaced earlier if there is a drop in water pressure.
You can use a variety of filters with this housing: AP810, AP811 and AP814 for sediment and rust; AP815 and AP817 for
Sediment, Chlorine Taste & Odor.
NOTE: Before changing cartridge, turn off water supply. Place a bucket under filter to catch the small amount of water
that will run out after housing removal.
1. Close shut-off valve after filter head.
2. Relieve pressure in filter housing by pushing red vent button.
3. Unscrew housing to the left and remove old cartridge. Wash housing thoroughly with mild soap and water.
4. Lubricate o-ring with a silicone based lubricant.
5. Insert new cartridge and re-install housing. Be sure cartridge and o-ring are seated in the housing before tightening
onto head.
6. Open main shut-off valve and check for leaks. If any leaks appear, tighten housing as needed. Open shut-off valve
after filter head.
7. Flush system for five (5) minutes.
Water Leaks at Fittings:
Tighten slightly until leak stops.
If Leaks Persist:
Shut off water at the main water supply shut-off valve, remove threaded fittings, reapply PTFE tape in a clockwise direc-
tion (to the right) and screw back onto head assembly.
CUNO Incorporated, a 3M Company, warrants that this product is free from defects in materials and workmanship. This
warranty, together with any and all warranties implied by law, shall be limited to a period of ten (10) years from the date
of original purchase. This warranty does not apply to failures that result from abuse, misuse, alteration or damage not
caused by CUNO or failure to properly comply with these installation or cartridge change-out instructions. This warranty
is subject to exclusions and limitations. Please refer to the Warranty Card provided with the product for details.
CAUTION

TROUBLESHOOTING GUIDE

LIMITED WARRANTY
10 Year Limited Warranty