filter and injection valve (see point 3). Screws and seals status check is also advisable each
3 months time or at the end of the season. The use of very aggressive or solid suspended chemicals require more frequent controls.
3.
As above mentioned, the wetted parts are to be maintained from time to time using the most appropriate cleaning reagent.
Considering the large number of chemicals available in the market a general advice is not possible.
That said, we can suggest in the case the pump works with sodium hypochlorite:
a.
Make sure that the pump is deactivated alectrically (both polarities) by detaching the conductors from the contact points of the
mains through an omnipolar switch with a minimum distance between the contacts of 3mm.
b. Disconnect the delivery pipe from the connector
c. Remove the suction pipe (with filter) from the tank and dip it into clean water
d. Start the peristaltic pump and have it work with water for 5-10 minutes
e.
With the pump disconnected dip the filter into a solution of 10% hydrochloric acid and wait for the acid to finish its cleaning
action
f.
Start again the pump making it work with 10% hydrochloric acid for 5 minutes, creating a closed circuit with suction and
discharge immersed in the same container
g. Repeat the operation with water
h. Connect again the peristaltic pump to the system
5.0 - MyPOOL pH - RX
5.1 - CONTROLS
1 - Button to increase the value
2 - Button to decrease the value
3 - Button MENU/ESC
4 - Button to CAL/OK
5 - Button to set the stpoint7 segments display
6 – Digital display
5.2 - CHARACTERISTICS OF MyPOOL
MyPOOL is a friendly user instrument, made by a peristaltic pump and an electronic controller able to measure and settle the chemical-
physical values of a swimming pool, like the pH and the ORP (mV) values. The pump operate in proportional mode.
MyPOOL pH factory defaults : Setpoint= 7,2pH; mode = ON/OFF; intervention: ACID
5.3 - OVERDOSING ALARM
If the value of the measure is below 5 pH or higher of 9 pH, the display will show a message of error low or high concentration of the acid
in the swimming pool. For the REDOX the only type of dosification is only oxidant direction, so it is possible only a low error for values
of mV below 100.
5.4 – STAND-BY
Press in the same time arrow up and arrow down.
5.5 - PRIMING
With the pump in stand-by at the same time press MENU/ESC and CAL/OK.
MyPOOL pH - RX
18
Fig. 4