Operating Instructions and Parts Manual
Installation
(Continued)
SUCTION PIPING
Install foot valve or
strainer screen over
intake of suction piping.
Never use pipe smaller than 2" in
diameter for suction piping. The suction
pipe must be kept free of air leaks. For
horizontal runs, lay pipe from the water
source so the upward slope is at least 1/4"
per foot. This eliminates trapped air. The
threaded inlet of the pump is 2" NPT.
Do not install
suction piping
near swimming areas.
DISCHARGE PIPING
Install a 1-1/2" pipe tee in the pump
discharge to allow easy priming. Plug
the end of the tee opposite the pump
to allow the branch piping to go to the
spray nozzles (See Figure 1). Remove
the pipe plug to fill the pump with
water for priming.
PIPE PLUG
1-1/2" PIPE
TEE
Figure 1
CONNECTION TO WATER SOURCE
The maximum vertical suction lift from
pump to the water level is 25 feet.
DRILLED WELL
1. Install a foot valve on the first
section of pipe (see Figure 2).
2. Lower the pipe into the well.
3. Add pipe until the foot valve is 10
feet below the lowest anticipated
water level.
Leaking joints or couplings will allow air
to leak into the pipe and cause poor
pump operation or difficulty priming.
Make sure to use pipe joint compound
or plumber's seal tape on all threaded
pipe connections.
Locate foot valve
no closer than 2 feet
from the bottom of the well so sand or
sediment is NOT drawn into the system.
www.waynepumps.com
FOOT VALVE
Figure 2
4. After the proper depth is reached,
install a well seal or pitless adapter
to support the pipe.
5. Slope the horizontal pipe upward
toward the pump to eliminate
trapping air.
TO SPRAY
6. When using a foot valve, a priming
NOZZLES
tee and plug above the well seal is
recommended.
DRIVEN WELL
• Drive the point several feet below
the water table.
SHORT
SECTION
NOTE: A packer-type foot valve can be
OF PIPE
installed in the well (See Figure 3). This
type of foot valve allows the well pipe
to be filled with water when priming
PUMP
and makes the inlet pipe much easier to
test for leaks. Follow the manufacturer's
instructions when installing the packer-
type foot valve.
DRIVE POINT
Figure 3
As an alternative, an in-line check valve can
TO PUMP
be used with a driven well (See Figure 4).
It may be necessary to supply the pump
WELL SEAL
with multiple well points to maintain
the high flow capability of this pump.
Consult with a plumbing professional
for appropriate materials and
installation instructions.
Leaking joints or couplings will allow air
to leak into the pipe and cause poor
pump operation or difficulty priming.
Make sure to use pipe joint compound
or plumber's seal tape on all threaded
pipe connections.
WELL
CASING
Dug Well, Cistern, Lake
And Spring Installation
TO PUMP
from the bottom of the well so sand or
sediment is NOT drawn into the system.
NOTE: When a lake is used for the water
supply, make sure the suction pipe is
deep enough to be submerged at all
times. Slope the pipe upward toward
the pump to eliminate trapping air. The
pipe must be removed during winter
months or protected against freezing.
PACKER
swimmers and boaters. Install a screen
TYPE FOOT
around the inlet pipe to prevent the
VALVE
entrapment of swimmers.
2
WLS Series
TO PUMP
INLINE CHECK
VALVE
DRIVE POINT
Figure 4
• Install a foot valve on the inlet pipe
and lower into the water.
Locate foot valve
no closer than 2 feet
Protect the pipe
from damage by