9.3.1 Integrated safety devices

Thermal fuse
The equipment is fitted with a 216ºC thermal fuse
(ref.52350036), located in the hot air chamber
(No.8). This fuse protects the equipment against
overheating caused by a malfunction or wrong
programming of the controller. It is intended to cut
the power to the resistance when the temperature
limit is reached.
After it having been rendered inactive by reaching
a temperature of 216ºC it must be replaced.
Please contact SAGOLA's Technical Assistance
Service (TAS).
Intensity fuse
The equipment is fitted with an intensity spike
fuse, which protects all the equipment in the event
of high consumption above 5A (220-240V)
ref.52350094 or 10A (110-130V) ref.52350095,
(short-circuit or malfunction of the resistance).
After it having been rendered inactive by reaching
an intensity of 5A or 10A it must be replaced.
Please contact SAGOLA's Technical Assistance
Service (TAS).
Disconnection due to lack of air circulation
The equipment team is fitted with a flow meter,
which protects the resistance from overheating, in
the absence of cold air consumption and subse-
quent insufficient cooling of the resistance. It
ensures energy savings when there is no air
consumption and protects it against undue starting
up (by error) of the equipment.
The trigger point of the flow meter is set to a value
of 150 L/min. If malfunction of the operation of the
flow meter is suspected, please contact SAGO-
LA's Technical Assistance Service (TAS).
"Cold touch" heat insulation to the outside
The design and construction of the equipment, as
well as the thermal insulation used, ensure that
the outer surfaces of the equipment are kept cold
during operation, with the exception of the
compressed air coupling, which will be kept hot.
The temperature of the outer surfaces of the
equipment shall in any event not exceed the
temperature selected on the temperature contro-
ller. If excessive heating of the outside surfaces of
the equipment is detected, turn off the equipment
and check its condition.
Protection of the controls
The equipment is fitted with a protective cover with
transparent glass that completely covers all the
temperature controller's controls, protecting these
from dust, vapours and occasional spills of liquids.
At the same time it protects against erroneous
programming by the unintentional pressing of the
temperature controller keys.
When programming the equipment, to prevent
breakage, damage or loss, we recommend that
you fit the protective cover on the anchoring plate
of the PACK 6000X AIR HEATER, in the groove
provided for this purpose.

9.4 OTHER REQUIREMENTS

- The equipment must be protected against the
spill or the projections of liquids.
- There must be sufficient ventilation.
- The intended use of the equipment requires that
all parts of the equipment must be assembled, in
adequate working conditions and do not display
deformities or breakage.
- The equipment must be used with an electrical
and compressed air supply that is activated, stable
and in accordance with established technical
specifications.
- For use according to that prescribed, one must
also comply with the indications contained in the
instruction manual and especially those on safety,
operation and control described in this manual.
- Before each start up and especially after any
repairs, one must check that all the components
are perfectly tightened.
- 22 -