7.5
Oil is leaking from the return line safety valve
/i
Possible cause
The return line is not connected (only for dual-
hose system).
If the tool was disconnected from the pump and
left in position, the remaining load on the tool may
be too high.
7.6
The deadman's handle is jammed or does not return automatically to the
neutral position
/i
Possible cause
The deadman's handle is faulty.
7.7
The carrying handle fails to rotate
/i
Possible cause
The mechanical plunger is not locked in one of the
grooves.
The unlock button (Fig. 2/9) does not rotate
together with the carrying handle.
8
Maintenance
8.1
General
For standard installation instructions, refer to the Service & Support section of the Holmatro website.
Proper preventive maintenance of the equipment preserves the operational safety and extends the life
of the equipment.
WARNING
When performing maintenance activities, always comply with the relevant safety regulations.
Wear the prescribed personal protection equipment.
36
Solution
Connect the return line.
Use a tool with a higher rated load.
Solution
Have it repaired by a Holmatro Certified
Technician.
Solution
•
Slightly lift up the deadman's handle.
•
Push the unlock button (Fig.2 /9) to the left or
the right.
•
Lift up the mechanical plunger or lower it to a
different height.
•
Release the unlock button. Make sure the
mechanical plunger is locked in one of the
grooves.