ANOMALIES AND SOLUTIONS
When there is a functioning anomaly, the
display controls shows and red led switch
on.
Descriptions of the anomalies with the rela-
tive alarms and solutions are given below:
– AL 01 (fig. 29)
Press the key
of the controls to re-
start the boiler.
If the anomaly persists, request the
intervention of qualified technical per-
sonnel.
– AL 02 (fig. 29/a)
If the water pressure detected is lower
than 0.5 bar, the boiler will stop and the
display will show "AL 02".
Bring the pressure back to normal by
means by acting on the telescopic type
loading knob.
Lower the knob and turn it anti-clockwise
to open until the pressure indicated by
the hydrometer is between 1 and 1.2
bars.
WHEN FILLING HAS BEEN COMPLETED
CLOSE THE KNOB
CLOCKWISE.
2
bar
1
3
0
4
88
In "12-20 T" vers. loading is achieved
by the cock mounted externally from
the installer.
If it is necessary to repeat the system
loading procedure, it is advisable to
contact qualified technical personnel
to check the seal of the heating system
(to check whether there are any leaks).
– AL 05
Request assistance from qualified
technical personnel.
– AL 06 (fig. 29/b)
Press the key
start the boiler.
If the anomaly persists, request assi-
stance from qualified technical person-
nel.
Fig. 29
– AL 07 (fig. 29/c)
Press the key
start the boiler.
If the anomaly persists, request assi-
stance from qualified technical person-
nel.
TURNING IT
Apre
OPEN
– AL 08
Request assistance from qualified
technical personnel.
– AL 10
Request assistance from qualified
technical personnel.
– AL 13 (fig. 29/d)
Press the key
Fig. 29/a
start the boiler.
If the anomaly persists, request assi-
stance from qualified technical person-
nel.
of the controls to re-
– AL 14
Request assistance from qualified
technical personnel.
– AL 15
Request assistance from qualified
technical personnel.
– AL 18
Request assistance from qualified
technical personnel.
GAS CONVERSION
Fig. 29/b
If it is necessary to change to a different
type of gas, request assistance only from
authorised technical personnel.
of the controls to re-
MAINTENANCE
Annual maintenance of the appliance
should be planned sufficiently in advance,
requesting the assistance of authorised
technical personnel.
The boiler is supplied with an electric wire
for the electrical power supply which, in
the case of replacement, must be substi-
tuted only by another obtained from the
constructor.
Fig. 29/c
of the controls to re-
Fig. 29/d