Wiring Connections (continued)
INSTALLATION WIRING - SINGLE PHASE, 3 WIRE
WARNING: For motors of 1-1⁄2 HP and above, use a magnetic starter to avoid damage to the pressure switch. Consult factory for wiring
information.
WARNING: Risk of electric shock. Can shock, burn, or kill.
Ensure the ground control box, all metal plumbing, and motor frame with copper wire are in compliance with local codes. Use a ground
wire at least as large as the wires supplying power to the motor.
Permanently close all unused openings in this and other equipment.
Disconnect power to the control box before working on or around the control box, pipes, cable, pump, or motor.
Copper Cable Length in Ft. (Service to Motor) G-Series Motors: 1 Ph, 2-Wire Cable, 60 Hz. Wire Size
HP
Volt
Wire Size, AWG
14
0.5
230
466
0.75
230
353
1
230
271
Copper Cable Length in Ft. (Service to Motor) G-Series Motors: 1 Ph, 3-Wire Cable, 60 Hz. Wire Size
HP
Volt
Wire Size, AWG
14
0.5
230
359
0.75
230
281
1
230
233
All cable lengths meet NEC for jacketed 60°C copper cable. Based on 3-Wire Induction Run requirements; Capacitor Run requirements may
vary. Local code requirements may vary. For aluminum cable, go up two sizes from the chart (for example, if the chart calls for No. 10 AWG
2
(6mm
) for copper, go to No. 8 AWG (10mm
connections.
CONTROL BOX INSTALLATION
To be sure that starting relay will function and that overload will not "nuisance trip", install a control box vertically with top side up.
Wire the control box as shown in the figures below. A 3-wire pump will not operate without a control box. Operation without a control box
will burn out a 3-wire motor. Installation must include circuit and component protection which meets local code and United States National
Electrical Code requirements.
If the main overload trips, look for:
1.
Shorted Capacitor
2.
Voltage Problems
3.
Overloaded or locked pump
12
10
8
742
1183
1874
562
891
1420
430
686
1087
12
10
8
571
912
1444
447
713
1129
371
592
937
2
) for aluminum; the smaller the number, the larger the cable). Use oxidation inhibitors on the
6
4
3
2915
4648
5843
2210
3523
4429
1692
2697
3390
6
4
3
2246
3581
4502
1757
2800
3521
1458
2324
2921
6
2
1
0
7379
9295
11733
5594
7046
8895
4281
5394
6808
2
1
0
5685
7162
9040
4446
5601
7070
3689
4648
5867
00
11222
8590
00
8920
7402

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido