Commissioning/start-up

How to proceed:
1. Close the slide valve for the DN 75 dirt outlet at the bottom of the container.
2. Check that the entire filter system (pipes and hoses) is complete.
3. Fill the container with water:
– Pump fed system: Switch on the filter pump.
– Gravity fed system: Open the slide valves (supply and return) of the filter series to allow the wa-
ter to flow.
4. Check all pipes, hoses and their connections for leaks.
– Expansion seals may leak initially until they have fully expanded on contact with water.
5. When all filter containers are filled with water, switch on the other electrical units (e.g. filter pumps).
If using filter starters (e.g. OASE BioKick), do not operate any UVC clarifiers for at least 24 hours so
as not to disturb the colonisation of the filter media by micro-organisms.
6

Remedy of faults

Malfunction
No flow of water
Water flow insufficient
No water is pumped out of the container.
7

Maintenance and cleaning

Dead biomass drops to the bottom and has to be removed. To do this, open the DN 75 dirt outlet for
approx. 10 seconds.
• The entire filter system only needs to be taken out of operation for cleaning and maintenance if it is
extremely soiled.
• Do not use any chemical cleaning agents as they would kill the filter bacteria.
7.1

Cleaning the container

How to proceed:
1. Switch off all filter pumps.
2. Switch off all other electrical units of the filter system (e.g. UVC clarifier).
3. Gravity fed systems only: Close the slide valves (supply and return) of the filters connected in series
to prevent further water flow.
4. Open the slide valve for the DN 75 dirt outlet at the bottom of the container and dispose of the
soiled water in a permissible way.
5. Pump fed system only: If necessary, dismantle the ClearWave filter elements. (→ ClearWave
disassembly and cleaning)
6. Carry out cleaning measures.
7. Close the slide valve (dirt outlet).
8. Start up the filter system again. (→ Commissioning/start-up)
24
Possible cause
Filter pump not switched on.
Supply to filter system or return to pond
blocked.
Bottom drain, pipe or hose blocked
Hose kinked
Excessive loss in lines
Filter pump in the container is defective.
Remedy
Switch on the filter pump, connect the
power plug.
Clean the supply and/or return.
Clean, replace if necessary.
Check hose, and replace if necessary.
Reduce line length to necessary mini-
mum.
Refer to the filter pump operating
manual.