FINISHED
CEILING
MATERIAL
CLEARANCE
HOLE
8. Finish ceiling.
Cut an opening in finished ceiling material for housing collar.
SPRINGS
9. Attach trim ring / baffle to housing.
Remove the cardboard protector from inside the housing collar.
Insert one end of each spring into the holes on the lamp bracket.
Center trim ring / baffle in ceiling opening.
10. Install bulb.
CAUTION - RISK OF FIRE:
75W MAX. LAMP
Use R30, BR30, PAR30L, or PAR30LN lamps only (75W Max.).
For wet locations (tub or shower) - use PAR30L or PAR30LN (75W
Max.) lamp only. Use no other lamp types.
Do not install a lamp indentified for use only in enclosed luminaries.
HOUSING
COLLAR
TRIM RING /
BAFFLE
LAMP
BRACKET
SERVICE PARTS
1
2
4
9
15
8
10
11
KEY NO.
PART NO.
1
97014185
2
97016382
3
98003036
4
98005512
5
99524804
6
99524805
7
99080557
97016454
8
99271323
9
99271322
10
99420551
11
99770033
12
97016491
97016453
13
99524802
14
99525160
15
98010583
Order replacement parts by PART NO. - not by KEY NO.
* Lamp Bracket Assembly must be removed to service these
parts.
MODEL 744
Page 4
Lamp Bracket Assem-
bly must be removed to
service these parts.
5
3
12
13
14
DESCRIPTION
Damper / Duct Connector
Housing Assembly
Mounting Bracket (4 req.)
Wiring Adaptor Plate
Blower Wheel *
Motor Bracket / Venturi *
Motor *
Motor / Motor Bracket Assembly
(includes Key Nos. 6 & 7) *
Receptacle
Thermal Protector
Plastic Wire Clip
Lamp Socket
Lamp Bracket
Lamp Bracket Assembly
(includes Key Nos. 8 thru 12)
Trim Ring / Baffle with Springs
Baffle Springs (2 req.)
Electrical Box Cover
99043318F
6
7