Electrical Connection - Oase AquaOxy 400 Instrucciones De Uso

Ocultar thumbs Ver también para AquaOxy 400:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 13
- GB -
Pos: 58 /Pumpen/Schlammsauger/Aqua Oxy 400/Inbetriebnahme Aqua-Oxy 400 @ 3\mod_1153384059394_121.doc @ 19681 @
Start-up
Prior to this observe the following operating steps: Connect the air hose to the unit prior to switching on. We recom-
mend to fit the aeration stones approx. 30 cm below the water surface. Keep the length of the air hoses as short as
possible. Protect the connection cable when burying and connect the transformer to a socket. Air will emerge from the
aeration stones after a short start-up time. The air quantity can be controlled by means of the regulating valves (G).
Pos: 59 /Pumpen/Schlammsauger/Aqua Oxy 400/Elektrischer Anschluss Aqua-Oxy 400 @ 12\mod_1255000731398_121.doc @ 77137 @

Electrical connection

Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures: Disconnect the power plug prior to reaching into the water and commencing
work.
Only entrust an authorised expert to carry out the electrical connection in accordance with the German EVU and VDE.
The VDE 0100, part 702, are valid for all installations. Deviations from the rated voltage +6% and -10%. Please refer to
the type plate for all capacity and performance data. Carry out all work on the unit when isolated.
Pos: 60 /Pumpen/Schlammsauger/Aqua Oxy 400/Reinigung Aqua-Oxy 400 @ 12\mod_1255000769727_121.doc @ 77165 @
Cleaning
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures: Disconnect the power plug prior to reaching into the water and commencing
work.
Disconnect the power supply first, then secure the unit to prevent unintentional switching on. Should the performance
reduce, clean the air intake opening in the base of the housing.
Pos: 61 /Pumpen/Schlammsauger/Aqua Oxy 400/Verschleißteile Aqua-Oxy @ 3\mod_1153316092005_121.doc @ 19521 @
Wearing parts
Diaphragms are wear parts and are excluded from the warranty.
Pos: 62 /Pumpen/Schlammsauger/Aqua Oxy 400/Austausch der Membranen Aqua-Oxy 400 @ 3\mod_1153384274719_121.doc @ 19759 @
Replacing the diaphragms
Diaphragms need to be replaced occasionally. Always replace diaphragms in pairs, left and right.
Disconnect the power supply first, then secure the unit to prevent unintentional switching on. Remove the hood by
unscrewing the screws from the unit underside (A). Open the metal housing by undoing the screws, then remove the
cover (B). Disconnect the connection hose from the pump heads (C) on the left-hand and right-hand side. Remove the
pump from the metal housing (D) and disassemble the pump heads by undoing the screws (E). The membrane can be
replaced after loosening the screws and removing the support disk (F). Ensure correct insertion (note the shape).
Reassemble the unit in the reverse order and put it back into operation.
Pos: 63 /Pumpen/Schlammsauger/Aqua Oxy 400/Lagern/Überwintern Aqua-Oxy @ 3\mod_1153315880091_121.doc @ 19495 @
Storage/Over-wintering
Take the air hoses out of the water and clean. Check the unit for damage and store it in a frost-free environment.
Pos: 64 /Alle Produkte/Entsorgung/Entsorgung - gem. Bestimmungen/Fachhändler @ 0\mod_1125578523312_121.doc @ 1407 @
Disposal
Dispose of the unit in accordance with the national legal regulations.
Pos: 65 /Pumpen/Schlammsauger/Aqua Oxy 400/Störung Aqua-Oxy @ 3\mod_1153315025902_121.doc @ 19469 @
Malfunction
Malfunction
Unit does not run
Unit does not deliver air
Insufficient delivered quantity
Pos: 66 /Alle Produkte/Dummy_module/===== Seitenwechsel ===== @ 0\mod_1125648978015_0.doc @ 1630 @
8
Cause
No mains voltage
Transformer defective
Diaphragms defective
Regulating valve (G) incorrectly set
Valves soiled
Diaphragms defective
Excessive loss in the supply hoses
Regulating valve (G) incorrectly set
Remedy
Check mains voltage
Replace transformer
Replace diaphragms, clean air slots
Check settings
Clean
Exchange diaphragms
Reduce hose length to a minimum
Check settings

Publicidad