PROGRAMMABLE FUCTIONS TO ADAPT TO THE TYPE OF INSTALLATION

TEMPERATURE REGULATION

The thermostat has been manufactured to work in
mod ON/OFF
(
) with thermal differential reading (
preset at
0. 5 °C ( setting from 0,2 °C to 1,2°C)
The hysteresis reading must be set on the basis of the thermal
inertia of the system; a low reading is advisable for systems
with radiators (eg, in cast iron) and a high reading for fan coil
systems.
°C
On
Off
Load
As opposed to the differential, the temperature can be
adjusted
minutes (default 10 minutes
differential
hysteresis
)
This system maintains the desired temperature more stable,
.
whilst increasing the user's comfort sensation and saving on
energy consumption
t = 20,5 °C Always off
t = 20,4 °C Use 1 min ON - 9 min OFF
t = 20,3 °C
t = 20,2 °C Use 3 min ON - 7 min OFF
Adjustable
t = 20,1 °C Use 4 min ON - 6 min OFF
differential
t = 20,0 °C Use 5 min ON - 5 min OFF
from 0,2 °C to
t = 19,9 °C Use 6 min ON - 4 min OFF
1,2 °C (0,3 °F
t = 19,8 °C Use 7 min ON - 3 min OFF
to 2,1 °F)
t = 19,7 °C Use 8 min ON - 2 min OFF
On
t = 19,6 °C Use 9 min ON - 1 min OFF
Time
t = 19,5 °C Always on
It is advisable to set a long cycle in systems with high thermal
inertia (cast iron radiators, floor heating systems) and a short
cycle in systems with low thermal inertia (fan coil).
proportionally PROP setting
(
)
)
Setting example:
t set = 20 °C - Cyclo = 10 min
Use
2 min ON - 8 min OFF
GB
cicles
from 7 to 20
°C
Use
20,8
OFF
20,6
20,4
20,2
20,0
19,8
19,6
Use
ON
19,4
19,2
0
2
4
6
8
10
Minutes
33