Appendix
Anhang
Additional UL requirements
1.
Installation
For a complete safe and vault installation connect to 'high security cable'. This
product shall be installed in accordance with The Canadian Electrical Code, Part 1,
Safety Standard for Electrical Installations.
2.
Programming - Sensitivity
Remote input (terminal 7) must not be able to be activated manually. It has to
be assured that remote input is only active while functional noise requires its
activation.
Remote input must not be activated permanently and is limited to 60 seconds.
2.1.
Sensitivity settings verified by UL for Monolithic Concrete:
Minimum
Maximum
thickness
spacing
2.5m
8.2ft
0.6m
1.98ft
4.0m
13.2ft
5.0m
16.5ft
For coverage of surfaces over corners, the recommended spacing is reduced
by 75%.
2.2.
Sensitivity settings verified by UL for Modular Steel Panels:
Minimum
Maximum
thickness
spacing
1.0m
0.006m
0.25in
1.5m
2.0m
A detector shall be on each modular wall panel that is not continuously
welded.
For coverage of surfaces over corners, the recommended spacing is reduced
by 75%.
2.3.

Sensitivity settings verified by UL for Steel Safes:

Minimum
Placement
thickness
Body
0.006m
0.25in
Door
Body
0.006m
0.25in
Door
Body
0.006m
0.25in
Door
At least one detector is to be mounted on the door and at least one detector is
to be mounted on the body.
* Note: Shock sensitivity is defined as the sensitivity to single impacts on the
detector or its base. Only in USER MODE, the shock sensitivity can be set
independently of Mode and Operating radius with the help of the ISN-SMS-W7
SensTool Software. If one of the fixed DIP setting is used, the shock sensitivity
corresponds to Mode and Operating radius as indicated in the tables above.
F.01U.326.907-03
Annexe
Appendice
Mode and
Shock
operating radius
sensitivity *
Concrete 2.5m
High
Concrete 4m
High
Concrete 5m
High
Mode and
Shock
operating radius
Sensitivity*
Steel
3.3ft
Low
1m
Steel
4.9ft
Mid
1.5m
Steel
6.6ft
Mid
2m
Mode and
Shock
Maximum
operating
sensitivity*
spacing
radius
Steel
1.0m 3.3ft
Low
1m
Steel
1.5m 4.9ft
Mid
1.5m
Steel
2.0m 6.6ft
Mid
2m