01. SAFetY wArnInG

As the Heat Pump contains electrical and rotational
equipment, it is recommended that ONLY competent
persons carry out any work on this type of machine
(see guarantee). Isolate electrically before entering
machine or removing panels.
02. InStALLAtIOn
1. Remove machine from packaging and locate
fixing bracket.
2. Locate bracket on wall in required position. Drill
hole Ø 6.0mm (no. 10) by 60mm deep as shown
at ‚A'. Insert wall plug and screw bracket in place.
3. Set bracket level with spirit level as shown, drill
through and fix it at ‚B' with wall plug and screw.
4. Ensure bracket still level, tighten screws ‚A' and
‚B', finally drill and fix as above at position(s) ‚C' & ‚D'.
5. Check all screws are tight.
6. Remove machine cover, retaining all fixings.
7. Lift dehumidifier on to wall bracket and mark
fixing holes.
8. Drill holes and fit wall plugs as stage 2.
9. Fit dehumidifier to wall.
10. Electrical supply to the unit must be sized according
to data on serial number label paying special
attention to I.E.E. regulations latest edition regar-
ding the special conditions governing electrical
supply to machines in potentially damp areas.
B - 1
11. The electrical supply should be connected to the
terminal block mounted on the bracket supporting
the compressor. Brown/red to ‚live', blue/black to
neutral and earth to the stud provided.
12. Locate pipe from drip tray and run it away to waste.
A short length of 10mm pipe is provided which
should be led into a fixed waste pipe.
13. Set Humidistat to, „drier", point on knob provided.
03. ttw-MAChIneS
Fit grilles, supplied with the Heat Pump, in position
required. Self-adhesive base supplied with the unit to
be fitted to the grill frame as shown in the diagram
below. Filters to be fitted to grille.
04. MAIntenAnCe
1. Ensure air inlet/outlets are kept clear and clean.
2. Wipe clean with damp cloth.
05. SInGLInG OUt PrOBLeMS
Machine not running at all – check the following:
1. Is supply switched on.
2. Is supply fuse healthy
3. Check air inlet and outlet for obstructions.
4. If, after carring out the above and waiting 1 hour,
the machine does not start, phone for service.
Machine fan only running:
1. Check air inlet and outlet for obstructions, if after
30 mins the machine has not restarted phone for
service.