Safety Notes; Description Of Apparatus - Trotec TTK 50 S Instrucciones De Uso

Tabla de contenido

Publicidad

Overview of contents
Safety notes ............................................. B - 1
Description of apparatus ........................... B - 1
Set-up ...................................................... B - 2
Operation ................................................. B - 2
Commissioning......................................... B - 2
Shutting down........................................... B - 2
Filter cleaning ........................................... B - 3
Transportation of apparatus....................... B - 3
Care & maintenance ................................. B - 3
Troubleshooting ........................................ B - 3
Technical data .......................................... B - 3
Circuit diagram ......................................... B - 3
Spare parts list ......................................... B - 4
Spare parts overview ................................ B - 4
Care and maintenance log ........................ B - 4
Pictures of apparatus
A
A.8
B.1
A.3
A.1
A.4
A.7
A.6
A.5
A.2
B.3
C
C.2
C.3
C.2
C.5
C.6
C.4
RUNNING
TANK
DEFROST
FULL
C.7
D
D.3
D.1
D.2
D.4
D.5
F
G
H
B - 1

Safety notes

This manual should be read carefully before setting
up / using the apparatus, and it should always be kept
close to the place of use or on the machine!
The apparatus was subjected to extensive material, function and
quality tests before delivery.
Nevertheless, dangers can arise from the use of the apparatus
if it is incorrectly used by untrained personnel!
Please observe the following instructions.
• The apparatus should not be set up and operated in
rooms where a danger of explosion exists.
• The apparatus should not be set up and operated in
saliferous environments or where the ambient air
contains oil, sulphur or chlorine.
• The apparatus must be placed upright in
a stable position.
• The apparatus should not be subjected to direct
contact with running water.
• Unrestricted access to the air intake and air exhaust
must always be guaranteed.
• The air intake side must be kept free of dirt and
loose objects.
• Never insert foreign objects into the apparatus.
A. Schematic representation of the principle of operation
B
A.1 Ventilator
B.2
A.2 Condensate container
A.3 Condenser
A.4 Evaporator
A.5 Condensate pan
A.6 Compressor
A.7 Humid room air
B.4
A.8 Dehumidified room air
C.1
B. Set-up
F
B.1 Keep windows closed
B.2 Keep doors closed
B.3 Keep apparatus at least 0.5 m away from walls
B.4 Keep apparatus away from heaters or other
sources of heat
C.5
C. Operation
C.1 Air intake
RUNNING
C.2 Operating console
C.3 Condensate container (tank)
C.6
C.4 Rotary-type control switch
C.5 Operating warning lamp
TANK
FULL
C.6 Tank warning lamp
C.7 Defrosting warning lamp
C.7
D. Set-up for operating mode
D.1 Turn all the way left, machine off
DEFROST
D.2 Turn all the way right, permanent mode
E
D.3 Hygrostat-controlled mode
D.4 Reduce dehumidification performance
D.5 Increase dehumidification performance
E. Cover for connecting piece
F. Filter slot
G. Filter groove
H. Filter cleaning
This publication replaces all previous announcements. No part of this publication
may be reproduced, processed using electronic systems, replicated or distributed
in any form, without our written authorisation. Subject to technical changes. All rights
reserved. Names of goods are used without guarantee of free usage keeping to
the manufacturer's syntax. The names of goods used are registered and should
be considered as such. We reserve the right to modify design in the interest of on-
going product improvement, such as shape and colour modifications. The scope
of delivery may vary from that in the product description. All due care has been
taken in compiling this document. We accept no liability for errors or omissions.
© TROTEC
®
Operating manual dehumidifier TTK 50 S
• The apparatus must never be covered or transported
during operation.
• All electrical cables outside of the apparatus are to be
protected from damage (e.g. by animals).
• Extension of the mains cables must be carried out with
due regard for the installed load of the apparatus, cable
length and application.
• The apparatus may only be transported upright, the
condensate container must be emptied before each
change of location.
• It is not permitted to operate or utilise the apparatus
in a manner other than that described in this manual.
All liabilities and warranty claims are invalidated in the
event of non-compliance with this stipulation.
Work on the refrigeration system and the electrical
equipment may only be carried out by an authorised
& qualified company!

Description of apparatus

The apparatus has been designed for automatic air
dehumidification. It can be easily transported and set
up due to its compact dimensions.
The apparatus works in accordance with the condensation
principle. It is equipped with a hermetically-sealed refrigeration
system, a low-noise, low-maintenance ventilator and a mains
cable with plug.
The apparatus has an operating console for function control.
The automatic control, the condensate container with inte -
grated overflow protection and the connection piece for direct
extraction of condensate permit fault-free continuous operation.
The apparatus conforms with the fundamental health & safety
requirements of the applicable EU legislation.
Application locations for the apparatus
The apparatus is used wherever dry rooms are required and
wherever subsequent economical damage (e.g. due to mould
formation) is to be avoided.
The apparatus is predominantly used to dry and
dehumidify:
• Living, sleeping, shower or cellar rooms
• Laundries, holiday homes, caravans and
motor homes, boats
And for the continuous drying of:
• warehouses, archives, laboratories
• Bathrooms, washing rooms & changing rooms.
Principle of operation
The unit works on the condensation principle (see Figure A,
schematic representation of the mode of operation). The
ventilator sucks the moist room air in through the air inlet,
via the air filter, the evaporator and the condenser that lies
behind it. In the cold evaporator heat is extracted from the room
air. The room air is cooled below the dew point, and the water
vapour contained in the air condenses as condensate or frost
on the evaporator fins.
The ambient air is cooled to below the dew point and the water
vapour contained in the air condenses as condensate or frost
on the evaporator fins.
The dehumidified, cooled air is warmed again at the
condenser (heat exchanger) and is blown out at a tempera-
ture of approximately 5 °C above room temperature.
This treated, dryer air is then mixed with the ambient air.
Due to the continuous room air circulation through the
apparatus, the air humidity in the place of use is reduced
continually to the desired relative humidity.
Dependent on the air temperature and the relative air humidity,
the condensed water drops continually, or only during the
periodic defrosting phases, into the condensate pan and then
into the condensate container located below via the integrated
outlet.
A float valve, disposed in the condensate container, interrupts
the dehumidification operation via a microswitch when the
container is full.