Overview of contents
Safety notes .............................................B - 1
Warranty...................................................B - 1
Description of apparatus ..........................B - 1
Set-up.......................................................B - 2
Operation .................................................B - 2
Commissioning.........................................B - 2
Shutting down ..........................................B - 3
Filter cleaning...........................................B - 3
Transportation of apparatus .....................B - 3
Care & maintenance.................................B - 3
Troubleshooting........................................B - 3
Technical data ..........................................B - 3
Circuit diagram .........................................B - 3
Spare parts list .........................................B - 4
Spare parts overview................................B - 4
Care and maintenance log .......................B - 4
Pictures of apparatus
A
A.8
B.1
A.3
A.1
A.4
A.7
A.2
A.5
B.3
A.6
C
C.1
C.2
C.3
C.2
C.5
C.6
C.4
C.7
D
D.3
D.1
D.2
D.4
D.5
G
H
B - 1

Safety notes

This manual should be read carefully before set-
ting up / using the apparatus, and it should always be
kept close to the place of use or on the machine!
The apparatus was subjected to extensive material, function and
quality tests before delivery.
Nevertheless, dangers can arise from the use of the apparatus
if it is incorrectly used by untrained personnel!
Please observe the following instructions.
• The apparatus should not be set up and operated in
rooms where a danger of explosion exists.
• The apparatus should not be set up and operated in
saliferous environments or where the ambient air
contains oil, sulphur or chlorine.
• The apparatus must be placed upright in
a stable position.
• The apparatus should not be subjected to direct
contact with running water.
• Free access for air intake and exhaust must be
guaranteed at all times.
• The air intake side must be kept free of dirt and
loose objects.
• Never insert foreign objects into the apparatus.
A. Schematic representation of the principle of operation
B
A.1 Ventilator
B.2
A.2 Condensate container
A.3 Condenser
A.4 Evaporator
A.5 Condensate pan
A.6 Compressor
A.7 Humid room air
B.4
A.8 Dehumidified room air
B. Set-up
B.1 Keep windows closed
B.2 Keep doors closed
B.3 Keep apparatus at least 0.5 m away from walls
B.4 Keep apparatus away from heaters or other
sources of heat
C.8
C. Operation
C.1 Air baffle flap
C.2 Operating console
C.5
C.3 Condensate container (tank)
C.4 Rotary-type control switch
C.5 Defrosting warning lamp
C.6
C.6 Tank warning lamp
C.7 Operating warning lamp
C.8 Setting the outlet direction
C.7
D. Set-up for operating mode
D.1 Turn all the way left, machine off
E
D.2 Turn all the way right, permanent mode
D.3 Hygrostat-controlled mode
D.4 Reduce dehumidification performance
D.5 Increase dehumidification performance
F
E. Cover for connecting piece
F. Filter flap
G. Filter groove
H. Filter cleaning
TRO-TR-BATTK100S-05-GB • This publication replaces all previous announce-
ments. No part of this publication may be reproduced, processed using electron-
ic systems, replicated or distributed in any form, without our written authorisation.
Subject to technical changes. All rights reserved. Names of goods are used with-
out guarantee of free usage keeping to the manufacturer's syntax. The names of
goods used are registered and should be considered as such. We reserve the
right to modify design in the interest of on-going product improvement, such as
shape and colour modifications. The scope of delivery may vary from that in the
product description. All due care has been taken in compiling this document. We
accept no liability for errors or omissions.
Operating manual dehumidifier TTK 100 S
• The apparatus must never be covered or transported
during operation.
• All electrical cables outside of the apparatus are to be
protected from damage (e.g. by animals).
• Extension of the mains cables must be carried out with
due regard for the installed load of the apparatus, cable
length and application.
• The apparatus may only be transported upright, the
condensate container must be emptied before each change
of location.
• It is not permitted to operate or utilise the apparatus in
a manner other than that described in this manual. All
liabilities and warranty claims are invalidated in the event
of non-compliance with this stipulation.
Work on the refrigeration system and the electrical
equipment may only be carried out by an authorised
& qualified company!
Warranty
The warranty period is 12 months. Damage due to incorrect
operation by untrained personnel, or commissioning of un au-
thorised persons, is excluded from the warranty.
The fault-free operation of the apparatus has been confirmed by
repeated tests at the factory. However, if a loss of function should
occur that cannot be resolved by the operator with the help of
the troubleshooting guide, please contact your dealer or autho-
rised agent.
Please quote the serial number of the apparatus when making
a claim (see model plate). The purchase receipt serves as evi-
dence of warranty.
Due to its design and layout, the equipment is intended to be
used solely for dehumidification purposes. The manufacturer is
not liable for any damages resulting from non-compliance with
manufacturer's instructions or legal requirements, or any alteration
to the equipment carried out by the user.
Opening up of the machine or unauthorised replacement of
components can substantially affect the electrical safety of the
product, and causes the warranty to be invalidated. The manu-
facturer is not liable for any damage to persons or posses -
sions caused by the apparatus being used in a manner con -
trary to the instructions set out in this operating manual.
The manufacturer reserves the right to make technical design
and model alterations without prior notice within the framework
of continuous product development.

Description of apparatus

The apparatus has been designed for automatic air dehumidifi-
cation. It can be easily transported and set up due to its com-
pact dimensions.
The apparatus works in accordance with the condensation
principle. It is equipped with a hermetically-sealed refrigeration
system, a low-noise, low-maintenance ventilator and a mains
cable with plug.
The apparatus has an operating console for function control.
The automatic control, the condensate container with inte -
grated overflow protection and the connection piece for direct
extraction of condensate permit fault-free continuous operation.
The apparatus conforms with the fundamental health & safety
requirements of the applicable EU legislation.
Application locations for the apparatus
The apparatus is used wherever dry rooms are required and
wherever subsequent economical damage (e.g. due to mould
formation) is to be avoided.
The apparatus is predominantly used to dry and
dehumidify:
• Living, sleeping, shower or cellar rooms
• Laundries, holiday homes, caravans and
motor homes, boats
And for the continuous drying of:
• warehouses, archives, laboratories
• Bathrooms, washing rooms & changing rooms.