3.10
CENTAC UNIVERSAL CLEARANCE SETTING TOOL
TAP 3/8-16 NC
1/2 "
1/2 "
1/4 "
1 3/4 "
2 1/4 "
3 1/2 "
1/4 "
Material: Common 1/4" bar stock
Use any combination of threaded and unthreaded holes in the clearance setting bracket
to apply bracket spring pressure on the thrust collar. This action keeps the thrust collar in
positive contact with the thrust bearing as the
thrust adjustment screws are moved in to
establish and set the impeller to
diffuser running clearance.
C950 Manual de Operación Rev. 2
© 1999 Ingersoll-Rand Company
Fecha de Publicación: 30-Aug-00
DRILL 9/16 "
3/8 " RADIUS
4 9/32 "
UNIVERSAL CLEARANCE SETTING TOOL METHOD OF USE
1 7/16 "
8.0 "
8 1/2 "
OPERACION
TAP 3/8-16 NC
1 "
Thrust bearing