Connections - Bpt IT/300 Manual De Instrucciones

Ocultar thumbs Ver también para IT/300:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 69
In order to access the terminals, remove the
terminal covers. The use of a 6/10 telepho-
ne cable is recommended for connecting
the telephones.
The maximum distance between the
telephone interface and the telephone is
100 m.
NOTE. The unit must be connected on ana-
logue telephone lines only and not digital
ISDN lines.
Functions of each terminal
Terminal block T (telephone line)
ae incoming telephone line
be incoming telephone line
au outgoing telephone line
bu outgoing telephone line
Terminal block IN
B video entry control line input
Terminal block A
~
mains
~
NOTE. When the jumper SW1 is ON, the
unit disables programming via the telepho-
ne.
IMPORTANT. WE RECOMMEND PROTEC-
TING YOUR TELEPHONE LINE AND
MAINS POWER SUPPLY FROM OVER-
LOADS WITH THE LP/MT LINE PROTEC-
TOR.

CONNECTIONS

Fig. 2
TL
Fig. 3
23
SW1
T
A
IT/300
T
bu
au
be
ae
IN
B
A
LP/MT
M3
M4
au
bu
M2
ae
be
M1
ON
OFF
IN
B
F2
F1