Press F1 ▶ to begin hoses flushing, the following screen will be displayed:
Hose flushing consists of 4 cleaning rounds, at the end of the 4 phases the following screen will be displayed:
NOTE: The hose flushing process takes approximately 10 minutes to complete. DUE TO THE SAFETY ISSUES RELATED TO HYBRID VEHICLES DO
NOT STOP THIS PROCESS.
Press F4 ↵ to continue with the AUTOMATIC PROCEDURE. The following screen will be displayed:
Open the high and low pressure taps on the machine and press F1 ▶ to begin the RECOVERY/RECYCLING process. During this phase, the graphic
display will show the following:
Upon completion of recovery, the machine will stop and automatically discharge the used oil from the A/C system if any was present during recovery.
The oil discharge operation lasts 6-14 minutes depending on the ambient temperature and the amount of refrigerant recovered. During the oil
discharge operation, the following screen will be displayed:
16
AUTOMATIC PROCEDURE
▶
Connect and open HP
and LP hoses to the
■
side of the machine
F1 to continue
F2 to exit
Hoses Flushing
Please Wait
■
ACP>26inHg
AUTOMATIC PROCEDURE
Disconnect hoses
■
from machine, then
connect to AC system
Press F4
Charge
RECOVERY/RECYCLING
Open high and low
▶
service port valves
■
Press F1
RECOVERY/RECYCLING
Ref recov. 00.00lb
■
Tp 87 psi T 68.7˚F
Acp 2 psi
↵
↑
↓
↵