MasterCool 69789 Instrucciones Para El Uso página 24

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

"B", three times for "C", four times for "2".
The following screen will be displayed:
Open the high- and low-pressure taps (if the A/C system is equipped with a single quick-connect coupling for high or low pressure, open only the
relative tap) of the machine and press F1 ▶.
Note: Charging may not run to completion due to pressure balance between the internal tank and the A/C system. If this occurs, close the valve
on the high pressure quick connect coupling (leaving the low-pressure side open), turn on the vehicle and switch on the A/C system. The unit is
equipped with a tank heater to limit this occurrence. When the charging operation is complete, the machine will display the following:
24
REF CHARGING
Ref Charging
Ref 01.79 lb
Open high and low valves
Press F1
REF CHARGING
END OF CHARGE
CLOSE HIGH AND LOW
SERVICE PORT VALVES
F1: TO CONTINUE
REF CHARGING
START ENGINE
TURN ON A/C SYSTEM
F1: TO CONTINUE
REF CHARGING
VERIFY A/C SYSTEM PRESSURES
F1: TO CONTINUE
REF CHARGING
CLOSE HP PRESSURE COUPLER
F1: TO CONTINUE
REF CHARGING
OPEN HIGH AND LOW
SERVICE PORT VALVES
TURN ON A/C SYSTEM
F1: TO CONTINUE