Description Of The Case - Astralpool POOLWATCH BASIC 16649 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5.2 INSTALMENT SCHEME NUMBER 2: DISINFECTION WITH TABLETS ORGANIC CHLORINE OR BROMINE
Net water
Recirculation pump
Flocculant unit
Balance tank
F lo c cu lant
Note: to install the become mobile valve as isolated as possible from the dispenser of tablets; not to place the tanks of chemical product under the dosing pumps
the chemical products must be far from the dosing pumps and of the equipment PoolWatch Basic Organ i c Chlorine
6.1 DESCRIPTION OF THE CASE POOLWATCH BASIC pH / ORGANIC CHLORINE-BROMINE
1. DISPLAY LCD: Back lightened display that shows the pH value and its set point value. It also shows the Organic Chlorine value
and its set point value. The arrow to the right of the set point value shows if an pH enhancer is being used when it is upwards and it is
downwards, shows that a pH reducer
2. 4 ARROW KEYBOARD: We can move in the display through these arrows when we enter the programme. They are double
function keyboard, hence the 2a button shows the value of the temperature in º Celsius; the 2b button shows the probe slope and
asimmetry, the 2c button shows the electrode reading (bias voltage) and the 2d button is used to cancel the Delay when it is switched
on. Pressing the four buttons at a time, you can see the equipment version and a manufacturing code.
3. ENTER BUTTON: It is used to enter the programme and for the programme itself.
4. VAL BUTTON: It is used to validate.
5. ESC BUTTON: It is used to go out of the programme.
6. pH PILOT: When it is enlighted, it shows that the pump relay is switched on.
7. Cl-BrPILOT: When it is enlightened, it shows that the Chlorine pump relay is switched on or motorized ball valve.
The symbols that are in use for showing the type of regulation are the following ones:
R
S
------------
PR
S
-----------
PA
S
--------------
Sw im m ing p ool
Sand filter
Continnuous flocculation
Motorized
ball
valve
' indicates regulation ON/OFF for exit relay
indicates proportional regulation for exit relay
' indicates proportional regulation for analogical exit (4-20mA)
7
Ref: PW Basic-16649-16650-28470-30831-gb-v2-T01
Channel overflow in continue
Dosing pump
Equipment
Tablets dispenserl
PW Basic
pH/ppm Cl Org
Tank pH
corrector
Safety basin
Drain
Flowmeter
Safety
valve

Publicidad