14. PROBLEMS AND SOLUTIONS POOLWATCH BASIC pH / ORGANIC CHLORINE-BROMINE
PROBLEMS
pH level above the programmed
value (if enhancer is used)
pH level below the programmed
value (if reducer is used)
Chlorine or Bromine level above the
one programmed
Chlorine or Bromine level below the
one programmed.
Led indicator of the pH or Cl pump
dispenser connector or the
motorised valve connector is on, but
the dispenser pump is not working or
the motorised valve is not open.
The motorised valve does not open
and the relay is on
The physicochemical analysis of the
pool water, that is the PW Basic.
Reading (There is too much
difference)
The alarm of wealth is activated,
d
there appears
iscontinuously"
ERROR N.02 LACK FLOW ".
It does not circulate water for the
hydraulic circuit of the equipment.
15. TECHNICAL CHARACTERISTICS OF THE POOLWATCH BASIC pH / ORGANIC CHLORINE-BROMINE
-
Measure range pH: 0 to 14 (resolution: 0.01 unit)
CAUSES
You selected a % of the dispenser pump higher
than the suitable one.
You selected a % of the dispenser pump higher
than the suitable one.
The input water valve to the dispenser is too
open or the tablets amount inside the dispenser
is too big.
The input water valve of the dispenser tablets
dispenser is not enough opened of the amount
of tablets inside is little.
a)
The connection bridge of the connectors 1-4
and 2-5 of the grids connectors has not been
done.
b)
Filtering stopped
c)
Delay activated
Improper connection
a) Dirty cartridge filter (see pages 5-6 point
nº 5)
b) Dirty electrodes
c) Expired electrodes.
d) Unproper photometer reading.
e) High water temperature > 28ºC
a)
There is no water running through the
analysis chamber
b)
Faulty connection to the flow detector
a)
Soiling of the filter mesh.
b)
Presence of particles in the
analysis chamber.
c)
Closed the valves of entry or exit
16
Ref: PW Basic-16649-16650-28470-30831-gb-v2-T01
SOLUTIONS
Reduce the % adjusting it to the pool
characteristics.
Reduce the % adjusting it to the pool
characteristics.
Close a little the input water valve to the
dispenser or reduce the amount of tablets
inside.
Open a little this water input valve or increase
the amount of tablets inside.
a)
Do the connection to the connectors 1-4 and
2-5 of the grid connector.
b)
If the filtering is in automatic mode, wait until
it starts working according to the selected
time, or switch the filtering on manually.
c)Switch off the delay pressing the button 2d.
Review power connection (see page 12).
a) Clean
b) Clean them with cleaning solution.
c) Change them.
d) Calibrate photometer
e) Insert the compensating value of water
temperature in the equipment through the
programming.
a) Check the hydraulic circuit circulation of
the PW Basic pH/Organic Chlorine
b) Verify and do the right connection to the
flow detector.
a) The filter Cleans mesh.
b) To clean the analysis chamber, must
dismantle the stopper of access to the float
(J).
c) To open the valves of enter and exit of the
hydraulic circuit.