Dual Technology Sensing
Switch Installation Guide
MS-B102
MS-B102-V
Occupancy
Vacancy
Lighting
120-277 V~ 50 / 60 Hz 6 A
Fan
120 V~ 50 / 60 Hz 4.4 A 1/6 HP
Combined lighting and fan load
120 V~ 50 / 60 Hz 4.4 A
Major motion coverage:
2
30 ft × 30 ft (9 m × 9 m) [900 ft
(81 m
Minor motion coverage:
2
20 ft × 20 ft (6 m × 6 m) [400 ft
(36 m
P/N 032442 Rev. A
12/2013
®
English
For additional features, wiring help,
troubleshooting, and product information
please visit:
www.lutron.com / DTMaestroInstall
Limited Warranty (Valid only in U.S.A., Canada, Puerto
Rico, and the Caribbean). Lutron will, at its option, repair or
replace any unit that is defective in materials or manufacture
within five years after purchase. For warranty service, return
unit to place of purchase or mail to Lutron at 7200 Suter
Rd., Coopersburg, PA 18036-1299, postage pre-paid. This
warranty is in lieu of all other express warranties, and the
implied warranty of merchantability is limited to FIVE years
from purchase. This warranty does not cover the cost of
installation, removal or reinstallation, or damage resulting
from misuse, abuse, or damage from improper wiring or
installation. This warranty does not cover incidental or
consequential damages. Lutron's liability on any claim
for damages arising out of or in connection with the
manufacture, sale, installation, delivery, or use of the
unit shall never exceed the purchase price of the unit.
This warranty gives you specific legal rights, and you may
have other rights which vary from state to state. Some
states do not allow the exclusion or limitation of incidental
or consequential damages, or limitation on how long an
implied warranty may last, so the above limitations may
not apply to you.
Lutron and Maestro are registered trademarks of
Lutron Electronics Co., Inc.
© 2013 Lutron Electronics Co., Inc.
Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299
P/N 032442 Rev. A
www.lutron.com
12/2013
Important Notes
Please read before installing.
®
1. Neutral wire required.
2. When power is applied, the sensing switch can
be manually turned on or off after the first
10 seconds and will automatically control the
load after 2 minutes.
3. CAUTION: Risk of Electric Shock — Turn
power OFF at circuit breaker before installing the
unit, rewiring, or replacing bulbs.
4. The sensing switch requires an unobstructed
view of the room and line-of-sight to detect
motion.
5. Hot objects or moving air currents can affect
the performance of the sensing switch and may
cause the sensor to turn on unexpectedly or
maintain its current state longer than desired.
6. CAUTION: To reduce the risk of overheating
and possible damage to other equipment, DO
NOT use to control receptacles.
7. Install in accordance with all national and local
2
)]
electrical codes.
8. For indoor use only. Operate between 32 °F and
2
)]
104 °F (0 °C and 40 °C).
9. Clean with a soft damp cloth only. DO NOT use
any chemical cleaners.
Troubleshooting
Symptoms
Possible Solutions
Power can't be switched
• Check wiring; neutral wire
ON or OFF with newly
must be connected for the
installed sensing switch.
product to function.
Not all of my sensor
• Sensor modes are limited in
modes are available
the Vacancy (MS-B102-V)
while programming.
model.
Lights do not turn ON
• Off-While-Occupied mode is
when space is occupied.
Enabled and the timeout has
not expired.
• Sensor mode is set to
Vacancy.
• You may have the Vacancy
model (MS-B102-V).
• Sensor is set to one of the
Ambient Light Detection (ALD)
settings and the room is too
bright for the current light level
setting.
• Sensor does not have full view
of the room. Move objects
blocking sensor's line-of-sight.
Sensing switch is
• If installed in a 3-way, with
unpowered, or is
another mechanical switch, be
powered, but does not
sure to rewire the mechanical
turn lights ON.
switch using Wiring step 2B.
Wiring
1
Turn power OFF
WARNING! Shock Hazard. May result in serious injury or death. Turn power OFF at circuit
breaker before installing the unit.
O
O
O
2
Connect sensing switch
• Before installing wallplate, program all desired settings. See back for programming instructions.
• For additional wiring instructions, please visit www.lutron.com/DTMaestroInstall
A. Single Pole Wiring
Black
Line/Hot
120-277 V~
50 / 60 Hz
Green
Ground
Neutral
B. 3-Way with Mechanical Switch
• Rewire your mechanical switch in a 3-way. 3-way wiring for sensing switch is different than
traditional 3-way wiring.
Single Circuit
Switch
Line/Hot
Black
Black
Blue
30
30
m
m
Hi
Hi
15
15
Med
Med
5
5
Low
Low
1
1
Off
Off
Mode
Mode
PIR
PIR
Occ
Occ
Hi
Hi
Lrn
LRN
Med
Med
120–277 V ~
Fixd
Fixd
Low
Low
White
Vac
Vac
Min
Min
50 / 60 Hz
Green
Ground
Neutral
3
Turn Power ON
O
O
O
4
Wait for 2 minutes
• The sensing switch will manually control the load after the first 10 seconds.
• Once power has been restored, the sensing switch will automatically control
the load after the first 2 minutes.
Black
Load
Blue
30
m
Hi
15
Med
5
Low
1
Off
Mode
PIR
Occ
Hi
Lrn
Med
White
Fixd
Low
Vac
Min
Standard
Mechanical Switch
Yellow
jumper
wire
(included)
Different
color
screw
Ground
Load

Publicidad

loading

Resumen de contenidos para Lutron Maestro MS-B102

  • Página 1 five years after purchase. For warranty service, return Not all of my sensor • Sensor modes are limited in Mode Mode wire unit to place of purchase or mail to Lutron at 7200 Suter 120–277 V ~ Fixd Fixd White modes are available the Vacancy (MS-B102-V) Rd., Coopersburg, PA 18036-1299, postage pre-paid.
  • Página 2: Change Settings

    (or stay off) can be adjusted through the “Set ALD Fixed Level” setting in Low (Default when in ALD Fixed mode) “Additional Settings” section. Minimum - turns lights ON only when room is dark Technical Assistance: www.lutron.com U.S.A., Canada, Caribbean: 1.800.523.9466 Mexico: +1.888.235.2910 Others: +1.610.282.3800...
  • Página 3: Remarques Importantes

    120-277 V~ 50 / 60 Hz 6 A dégagée de la pièce et de son champ de vision instructions de programmation. pour détecter les mouvements. • Pour des instructions de câblage supplémentaires, veuillez consulter www.lutron.com/DTMaestroInstall Ventilateur 5. Les objets chauds ou le déplacement des A. Câblage unipolaire 120 V~ 50 / 60 Hz 4,4 A 1/6 HP courants d’air peuvent affecter les performances...
  • Página 4: Changer Les Réglages

    être réglé dans le réglage « Régler le niveau ALD fixe » dans la section « Réglages supplémentaires ». Minimum – allume l’éclairage uniquement lorsque la pièce est sombre Assistance technique : www.lutron.com États-Unis, Canada et les Caraïbes : 1.800.523.9466 Mexique : +1.888.235.2910 Autres : +1.610.282.3800...
  • Página 5: Cableado Unipolar

    Negro Negro interruptor sensor Garantía limitada (válida sólo en E.U.A., Canadá, Puerto Rico y el Caribe). Lutron, a su elección, reparará o reemplazará recientemente cualquier unidad que resulte defectuosa por materiales o instalado. por mano de obra dentro de los primeros cinco años a partir...
  • Página 6: Selección De Configuración Personalizada

    "Cómo establecer un nivel fijo de detección de luz ambiental (ALD)" en la sección Bajo (de diseño en el modo ALD fijo) "Valores de configuración adicionales" Mínimo - enciende las luces solamente cuando la habitación está obscura Asistencia técnica: www.lutron.com E.U.A., Canadá, el Caribe: 1.800.523.9466 México: +1.888.235.2910 Otros: +1.610.282.3800...

Este manual también es adecuado para:

Maestro ms-b102-v