To program the limit position fitted with a mechanical system:
01. Press and hold the Up (or Down) key to move the shutter to mid-travel.
02. Press and hold the key (Up or Down) until the shutter stops on impact
with the limit position ("0" or "1") then release the key.
To program the limit position without a mechanical system:
01. Press and hold the Up (or Down) key to move the shutter to mid-way.
02. Press and hold the key (Up or Down) to move the shutter to the required
limit position then release the key.
03. Press and hold the Up and Down keys simultaneously for at least 3 sec-
onds and release after the motor has executed a brief movement in the
opposite direction.
04. At this point activate an Up or Down manoeuvre (depending on the posi-
tion of the shutter) and immediately afterwards a manoeuvre in the oppo-
site direction to enable the control unit to memorise the two limit positions.
CAUTION! - Do not interrupt these two manoeuvres and do not dis-
connect the power supply from the automation during movement.
10 – English
4.3 – TOTAL MEMORY DELETION
CAUTION! – This procedure deletes all data from the control unit memory,
including positions "0" and "1".
Note – If positions "0" and "1" are deleted, the main switch must be pressed
continuously (hold-to-run mode) for the entire time required to complete the
manoeuvre.
01. Press and hold the Up and Down keys simultaneously for at least 3 sec-
onds and after the motor has executed a brief movement release one key
only.
02. Within 3 seconds after the motor has executed the movement, press the
previously released key three times.
03. Then release the other key.