Air Filter Maintenance - Ryobi 704r Manual Del Operador

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

MAINTENANCE AND REPAIR INSTRUCTIONS

AIR FILTER MAINTENANCE

Removing the Air Filter/Muffler Cover
WARNING: To avoid serious personal injury,
always turn your trimmer off and allow it to
cool before you clean or service it.
1. Place the choke lever in the PARTIAL choke position (B).
NOTE: The choke lever must be in the PARTIAL choke
position (B) to remove the air filter/ muffler cover.
2. Remove the four (4) screws securing the air
filter/muffler cover (Fig. 19). Use a flat blade or
T-20 Torx bit screwdriver.
3. Pull the cover from the engine. Do not force.
Choke Lever
Screws
Cleaning the Air Filter
Clean and re-oil the air filter every 10 hours of operation.
It is an important item to maintain. Failure to maintain the
air filter will VOID the warranty.
1. Remove air filter/muffler cover. Refer to Removing
the Air Filter/Muffler Cover.
2. Turn cover over and look inside to locate the air filter.
Remove the air filter from inside the air filter/muffler
cover (Fig. 20).
3. Wash the filter in detergent and water (Fig. 21). Rinse
the filter thoroughly. Squeeze out excess water. Allow
it to dry completely.
4. Apply enough clean SAE 30 oil to lightly coat the filter
(Fig. 22).
5. Squeeze the filter to spread and remove excess oil
(Fig. 23).
Partial Choke
Position (B)
Screws
Fig. 19
Air Filter
Inside Muffler
Cover
Fig. 20
Fig. 22
6. Replace the air filter inside the air filter/muffler cover
(Fig. 20).
NOTE: Operating the unit without the air filter and air
filter/muffler cover assembly will VOID the
warranty.
Reinstalling the Air Filter/Muffler Cover
1. Place the air filter/muffler cover over the back of the
carburetor and muffler. Align the screw holes.
2. Insert the four (4) screws into the holes in the air
filter/muffler cover (Fig. 19) and tighten.
Do not over tighten.
Fig. 21