Indications and Faults –
All Charging Modes
LCD Screen Shows:
DXAEC210_ManualENFRSP_092116.indd 18
Indication | Solution:
Temperature Compensation Activated: The " " Icon will appear if the surrounding ambient temperature
is higher than approximately 40°C. The " " Icon will appear if the surrounding ambient temperature is lower
than 0°C. This is not a fault code, but indicates that the unit's temperature compensation feature is operating.
No user action is required.
Overheat Protection Activated: If the charger is overheated, the charging process automatically terminates.
The Fault Icon and the Overheat Alarm Icon flash. The (full) Battery Icon, Clamp Icons and the Battery Type
Indicator light solid.
Disconnect all battery charger connections and allow the charger to cool for several minutes. Make sure there
is adequate ventilation around the unit before attempting to charge again.
Battery Problem Detected: The charger automatically checks the battery condition 3 minutes after the charging
process starts. If the charger detects a problem with a battery, the charging process automatically terminates.
The Fault Icon and the (empty) Battery Icon flash. The Clamp Icons and the Battery Type Indicator light solid.
Disconnect all battery charger connections. Have the battery checked by a qualified technician.
Possible Battery Problem Detected: If the battery is not fully charged after 18 hours of continuous charging,
the battery may have internal damage and will not accept a charge. After 18 hours, the charging process
automatically terminates. The Digital Display shows "F04" and the Battery Type Indicator lights solid. The Fault
Icon and the (empty) Battery Icon flash.
Disconnect all battery charger connections. Have the battery checked by a qualified technician.
18
10/19/2016 3:58:54 PM