INSTALLATION AND CONFIGURATION POSIBILITIES OF THE MODULE OF
Push-
buttons
INTERNAL
Keyboard
Push-
buttons
EXTERNAL
Keyboard
CONTROL COMPACT REF:600013
Each push-button calls the monitor/phone code indicated by
Without
the position of that push-button. See page 35. This is the
Database
default setting. Emulates the old ref: 600005
Each push-button calls the monitor/phone that has been
entered in the database. The field "m/t" is filled with the
With
monitor/phone code and the field "call" with the position
code of the push-button.
Database
The calling code entered on the keyboard will be the
monitor/phone code directly. Valid codes are 1 to 254.
Without
Emulates the old ref: 600006.
Database
Functioning as the old DecorPlus. DB shall be filled with
calling codes up to 6 digits assigning each one a
With
monitor/phone code.
Database
This case is not allowed. If you install a push-buttons
Without
external panel the DB must be filled.
Database
Each push-button calls the SDL and monitor/phone that has
been entered in the database. The field "m/t" is filled with
the monitor/phone code, the field "SDL" with the SDL code
With
and the field "call" with the position code of the push-
Database
button.
The system will ask you to introduce the building code
(SDL) and the flat code (monitor/phone) you wish to call.
Without
Emulates the old ref: 600007
Database
Functioning as the old DecorPlus. DB shall be filled with
call codes up to 6 digits assigning each one a SDL code and
With
a monitor/phone code.