The Installer
A pair of programming codes will be provided to the Installer in order to give him
access to two different menus: The Configuration Menu & The Directory Menu.
By default, the code to enter to the Configuration Menu is '1', and the code to get
access to the Directory Menu is '9'. To Enter these codes we should first press C, and
then  (C+ should not be pressed at the same time). A line ("---------") will
appear asking for these codes. We can change these codes later in the Configuration Menu
to longer ones. At least four digits in these codes are strongly recommended.
This menu has been created to set the following 7 Panel Parameters:
OPEN CODE. 4 different common "Open Codes" up to 6 digits, to be assigned to
o
the postman or to the doorman, but not usually to the neighbours of the building.
By default these codes are 101010, 202020, 303030, and 404040. Set any
open code to the value 0 implies to disable it.
OPEN TIME. 2 different configurable "Open Times". The first one will be used
o
when the user is outside the building
building (pressing the hall-button inside the building. This open time is usually
longer). By default the Time1=2 seconds and the Time2 = 5 s. (Max Time for
both = 9 seconds).
PANEL NUMBER. Shows the panel number configured in the dip-switch. From 0
o
to 15.
PANEL internal / external. The Panel should be configured as 'external' if it
o
performs the call through an SDL (connected to the X (external) line of the SDL)
otherwise the Panel will be configured as 'internal'. From the v2.0, the screen will
also show the software version and an internal identification code.
SELF STARTING. The self-starting can be enabled or disabled in this menu.
o
SWITCHBOARD. This option should be enabled if the installation has a
o
switchboard linked to the DecorPlus panel. This means that any call code (even a
non existing one) will make a call to the switchboard. If this option is configured
as 'SWITCHBOARD: no' there it is still the possibility to assign the call code '0' to
a telephone / monitor that will work as if it was a switchboard. The non existing
codes introduced in the panel, will also be redirected to this telephone / monitor. If
the installation needn't switchboard functions, it is recommended to set
'SWITCHBOARD: no' and be sure not having any call code '0' in the data base.
NEW ACCESS CODE.
o
Configuration & Directory menus. Keep in mind that these codes were, by default,
'1' and '9' respectively.
5
That is when we call to a flat and someone opens the door, also when we introduce our personal Open Code
or a general Open Code.
6
If there is a guard porter button in the installation and it is pressed: If 'SWITCHBOARD: yes' it will make a
call to the guard porter, if 'SWITCHBOARD: no' it will call to the telephone / monitor with the call code 0 only
if it exists in the data base.
PLACA COMPACT – COMPACT PANEL
CONFIGURATION MENU
C +  + CODE + 
5
and the second one if the user is inside the
It is strongly recommended to change the codes of the