So if we press C + + 9 + , the system displays a screen showing the user the
following options: Add: 1, Erase: 2, Display/Change: 3.
Add: 1. When pressed, a screen will appear showing four more choices:
Manual: 4. Pressing '4', we get access to a template of a register that shows
o
us some values filled by default that we can change with the numeric
keyboard. Monitor/Telephone = 1, SDL = 1, Call Code=555555, Open
Code= Variable (it is different for each software version). If the panel is
configured as 'internal' the field 'SDL' will not be shown. We exit this mode
placing the cursor in the 'open cod.' field, and pressing C. After doing this, the
template we were editing will automatically remain stored in the Data Base.
Auto: 5. Pressing '5' we enter the automatic code generation mode. The
o
system will ask the number of SDLs that we have in our installation, the
number of Floors per SDL, and the number of Flats for each Floor. When these
questions are answered, the program will automatically generate registers with
6 digits codes for all the flats in the installation, using the first two digits for
the SDL number, the next two for the Floor and the last two for the Flat. In
example, the system will generate the code 020301 for the flat one in the third
floor of the second SDL. The open codes generated with this option will always
be '0' (disabled), and must be edited manually with a number different from '0'
if the user wants to enable them. Be aware that the codes that have been
created will be added upon the existing ones and this could be a mess. That's
why the system asks first of all if the user wants to erase the entire data base
or not. If the question is answered with all the registers will be deleted, if
the key pressed is '0' no register will be erased, any other key will exit to the
Directory Menu.
Remote: 6. If the '6' key is pressed; the system halts waiting for the RS232
o
transmission and shows the message 'Reception '. We can now use the PC
to send a single register or a complete data base of registers with the
'DecorPlus' application. If everything worked correctly the screen will change
to 'Reception OK' one second and a sound should be heard. During the
transmission, if any key is pressed information about the number of registers
that have been transmitted will appear on the screen. Press C to exit the
reception mode. More information can be found in the user's manual of the
DecorPlus Application.
Other: 7. If pressed, the system will show two more options: 1-254:8 and
o
PPC: 9.
1-254: 8. If the '8' key is pressed; the system enters the 'Default
Code Generation Mode'. In this mode, the Call Code 1 will be assigned
to the flat 1, the Call Code 2 to the flat 2 and so on, until the Call Code
254 is reached (obviously assigned to flat 254). The database will be
previously erased (it will ask for confirmation before doing it).
PPC: 9. If the '9' key is pressed; confirmation will be asked to
transmit all the database (with ). Pressing '0' we can navigate
through the DB (using C) and select the desired register to transmit
(using ). Pressing any other key we can exit this mode. In order to
send the DB to a PC the PC Directory v20 application must be
used.