3.2. - To make a concrete slab with the same level.
KEOPS
3.3. - Put the bin
3.3. - Put the bin
3.4.-You have to carry out the digging for preparing the canalization of the inlet
and outlet piping and the electrical supplier.
The inlet and outlet piping must be installed under a sand-bed.
Connect the catch basin to a general outflow with a light declination.
3.5. Bore the bin in the side in which the electrical supplier it is planned to enter.
The hole it has to be of the same diameter as the cable installed. The section of
the cable is choosen in accordance with the consumed power and the fall of
pressure. Install in the foreseen entrance a packing gland adapted to the cable's
KEFREN
3
section. It is recommendable to protect the cable in the entire course with a
suitable pipe.
IMPORTANT:
The installation must have a high sensibility balance gear of two poles asunder in
the general chart (according to rule RBT ITC-BT-017). The balance gear is not
supplied with the compact.
Refill the bin's lateral with gravel. In the case of especially smooth areas one
recommends to construct walls of containment or, in the Keops bin put a interior
metalic reinforcement (ref.xxxxxx).