Parameters Saving; Controlling The Device - Televes T.OX Serie Manual De Instrucciones

Ocultar thumbs Ver también para T.OX Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

DVBS2 - COFDM CI
f. LCN menu
Assign a LCN (Logical Channel Number) (between
1 and 1023) to the existing services at the output
(marked as ON or DCY).
To change the LCN press keys
and
lect "0000" as LCN will show "NO LCN".
g. Language menu
The last extended menu enables the menu
language to be selected (Spanish / English /
German / French):
Pressing keys
and
changes the selected
language.

5.3. Parameters saving

Once a parameter is modifi ed to the desired value
in any menu (normal or extended), to save the
settings press
for three seconds. The display will
show the following indication:
or
. If se-
If the confi guration paremeters are modifi ed but
not saved, the previous confi guration is retrieved
after 30 sec. in other words, the changes are
discarded.

6. - Controlling the Device

This version of the DVBS2-COFDM CI T0X allows
confi guration and monitoring via a PC, both locally
and remotely.
a. Local control
The "Headend Management" programme (v2.13
or higher) is required, as well as a special cable
(provided with the programme) that connects a
PC serial port to the DVBS2-COFDM CI T0X "PRGM"
connector.
The programme can be used to set up and read all
the operating parameters, as well as to monitor the
correct operation of the device.
b. Remote control
It is necessary to have a Headend Control module
(ref. 555901) that includes the programme
mentioned above, and the corresponding modem
connected to a phone line.
Once the communication with the headend
control has been established, all the controllable
devices that have been installed in the headend
can be accessed. In this case it is essential that each
element be programmed with a diff erent device
address between 1 and 254.