10. Repairs
Repairs to electrical tools must be carried out
by qualified electricians ONLY!
If you have Metabo electrical tools that require
repairs, please contact your Metabo service centre.
For addresses see www.metabo.com.
You can download spare parts lists from
www.metabo.com.

11. Environmental Protection

Metabo's packaging can be 100% recycled.
Scrap power tools and accessories contain large
amounts of valuable resources and plastics that can
be recycled.
These instructions are printed on chlorine-free
bleached paper.
Only for EU countries: Never dispose of
power tools in your household waste! In
accordance with European Guideline 2002/
96/EC on used electronic and electric equipment
and its implementation in national legal systems,
used power tools must be collected separately and
handed in for environmentally compatible recycling.

12. Technical Specifications

H 16-500
Output:
Air temperature:
Air volume:
Thermal protection: only thermal fuse
Weight
Sound pressure level:< 70 dB (A)
Vibration:
HE 20-600
Output:
Air temperature:
Air volume:
12
1600 W
Stage 1: ................... 300 °C
Stage 2: ................... 500 °C
Stage 0: ......................... Off
Stage 1: ................240 l/min
Stage 2: ................450 l/min
700 g (24.7 oz)
2
< 2.5 m/s
2000 W
(110V: 1400 W)
Stage 1: ..................... 50 °C
Stage 2: .............. 50-600 °C
Stage 3: .............. 50-600 °C
Stage 0: ......................... Off
Stage 1: ................150 l/min
Stage 2: ................300 l/min
Stage 3: ................500 l/min
Temperature
adjustment:
stepless in 9 stages
per adjusting wheel
(Tolerance +/- 20°C)
1 = approx. 50 °C
2 = approx. 90 °C
3 = approx. 140 °C
4 = approx. 220 °C
5 = approx. 310 °C
6 = approx. 390 °C
7 = approx. 470 °C
8 = approx. 550 °C
9 = approx. 600 °C
Thermal protection: only thermal fuse
Weight:
850 g (30 oz)
Sound pressure level:< 70 dB (A)
Vibration:
< 2.5 m/s
HE 23-650 Control
Output:
2300 W
Air temperature:
Stage 1: ..................... 50 °C
Stage 2: .............. 50-650 °C
Blower:
steplessly adjustable
Air volume:
Stage 1: .........150-250 l/min
Stage 2: .........150-500 l/min
Programs:
1=250 °C /
2=350 °C /
3=450 °C /
4=550 °C /
Temperature
display:
LCD in 10 °C steps
Thermal protection: yes
Weight:
940 g (33.2 oz)
Sound pressure
level:
< 70 dB (A)
Vibration:
< 2.5 m/s
Changes due to technological progress reserved.
Measured values determined in conformity with EN
60745.
Machine in protection class II
The technical specifications quoted are subject to
tolerances (in compliance with the relevant valid
standards).
2
approx. 350 l/min
approx. 400 l/min
approx. 500 l/min
approx. 400 l/min
2

Publicidad