Technical Data; Maintenance / Care - Würth ERGOPOWER TWINBLADE+ Manual De Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 15
NOTES REGARDING OPERATION
The switched-on lamp is very bright and the lamp
may get hot in the vicinity of the light outlet. When
the lamp is switched on:
• do not look directly into the light outlet.
• ensure that nobody is exposed to glare.
• do not cover the light outlet.
do not put down the lamp with the light outlet
pointing downwards.

TECHNICAL DATA

Number of LEDs
Battery specification
Input voltage power supply unit 100 - 240 V AC, 50/60 Hz
Input voltage lamp
Current consumption of lamp
Charging time power supply unit ~ 4 h
Charging time charging pad
Operating time main light
Operating time spot light
LED intensity main light
LED intensity spot light
Service life of LED
Degree of protection
Storage temperature
Operating temperature

MAINTENANCE / CARE

Visual inspection before starting work
The lamp is maintenance-free. The lamp and its acces-
sories must nevertheless be checked for external dam-
age before each use.
The lamp may not be used when damage
is visible. It must be repaired or disposed of by a
commissioned and trained person. Please contact
your Würth branch.
Cleaning
Cleaning work may only be performed when the
lamp is switched off and the mains connector has
been disconnected. Clean the lamp by wiping it with
a soft, clean cloth. Remove stubborn dirt with a mois-
tened cloth and a common household cleaner. Using
cleaning agents that are abrasive or contain alcohol
or solvent will damage the housing.
10
2x COB LED
Li-Ion 3.7V/4400mAh/16.28 Wh
5 V DC
1 A
~ 6.5 h
2 - 15 h
8 h
100 - 1000 lm
150 lm
≤ 10000 h
IP20 / IK08
–20 °C ... +45 °C
–10 °C ... +40 °C
DISPOSAL
Do not dispose of the lamp with domestic
waste!
Small electrical devices and packaging must
always be recycled in an environmentally
appropriate manner. Electrical tools that are
no longer usable must be separately col-
lected and forwarded for environmentally appropri-
ate recycling according to the European Directive
2012/19/EU.
WARRANTY
We offer a warranty according to the legal/
state-specific regulations from the date of purchasing
(proof by invoice or delivery note) for this lamp. A
damaged lamp is either repaired or replaced with
a substitute lamp. Damage resulting from improper
handling is excluded from the warranty. Complaints
can only be accepted if the lamp is handed over
assembled to a Würth branch, your Würth sales rep-
resentative or a Würth-authorised customer service
centre.