VIDEO SIGNAL STABILISATION
If an image on the monitor is misshaped, displace jumper, placed on the
monitor fixing plate (R684, R682), to one of the following alternative posi-
tions "B" or "C".
On installations where several monitors are
connected in series between them, place
only the jumper of last monitor to the "B" or
"C" position and kepp the other jumpers of
other monitors in the "A" position.
On installations with more monitors connect-
ed in star configuration, place the jumper to
the "B" or "C" position only on the monitor
with misshaped image.
MONITOR INSTALLATION (FIG. 1-2)
- The monitor should be installed far away from sources of light, heat and
electrical disturbances.
- Fix metal hooking plate to the wall with fixing screws supplied, keeping
top of panel at 1,40 m. from ground level.
- A drilling is forseen in order to fix the plate to a module flush-mounted
back box.
- Carry out connections on monitor terminal block following the diagrams.
- Hook the monitor following the arrow 1 and 2 direction .
- To remove the monitor from the hooking plate, operate with a screwdriv-
er on the security lock and remove it following the arrows 1 and 2 in the
opposite direction.
The monitor can be transformed into desk-top version by using the proper
conversion kit type 661A (Fig. 4).
1,40
1
8
Fig. 1
1
1
1
Fig. 2
D
E
C
CAMERA TECHNICAL FEATURES (Art. 68TC).
-
CCD 1/3,5" color sensor
-
3,7mm F4.5 auto-iris lens with non-adjustable focus
-
Video signal standard PAL type G, 625 lines, 50 images
-
Manual traversing on the vertical and horizontal axis
-
Effective picture: 500(H)x582(V) PAL
-
Horizontal resolution: 350 TV lines or Greater
-
Electronic iris (shutter).
2
-
Video output voltage 1Vpp on 75Ohms
-
Operating temperature -5° +45°C
-
Minimum lighting level 4 lux
-
Subject lighting by means of white light LEDs
- Name-tag lighting through LEDs
-
Built-in speech unit
-
Removable terminal block
-
Monitor call push-button.
2
-
Output for control of lighting floodlight by relay type 0170/101
- Lock release control with same timing as command from the monitor (1
second, not adjustable).
-
Supply voltage from the bus.
-
External dimensions: 80x120x25 mm.
Fig. 3